background image

2

English

Assembly 

(see page 4)

 

Safety Notes

 

Gloves should be worn during installation to prevent 

crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 

and body cleaning purposes.

 

The hot and cold supplies must be of equal 

pressures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 

surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 70°C 

Recommended hot water temp.: 

65°C 

Thermal disinfection: 

max. 70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking 

water!

Symbol description

Do not use silicone containing acetic acid!

Adjustment 

(see page 6)

To adjust the hot water limiter. Using a hot water limiter 

in combination with a continuous flow water heater is 

not recommended.

Dimensions 

(see page 10)

Flow diagram 

(see page 11)

Maintenance 

(see page 8)

The check valves must be checked regularly according 

to DIN EN 1717 in accordance with national or 

regional regulations (at least once a year).

Spare parts 

(see page 12)

Cleaning 

(see page 14)

Operation 

(see page 7)

Fault

Cause

Remedy

Insufficient water

- check valve hasn't moved back

- Exchange check valves

- Regulator filter dirty

- Clean filter seal between shower 

and hose

- Shower filter seal dirty

- Clean filter seal between shower 

and hose

Mixer dripping

- Cartridge defective

- Exchange cartridge

Mixer stiff

- Cartridge defective, calcified

- Exchange cartridge

Hot water temperature too low

- Hot water limiter incorrectly set

- Set hot water limiter

Instantaneous heater didn’t work

- Flow limiter in handshower isn’t 

removed

- Remove flow limiter

- Shower filter seal dirty

- Clean filter seal between shower 

and hose

- check valve hasn't moved back

- Exchange check valves

Summary of Contents for Focus 31924009

Page 1: ...EN Instructions for use assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 3 Focus 31941009 31942009 Focus 31924009 31925009...

Page 2: ...ption Do not use silicone containing acetic acid Adjustment see page 6 To adjust the hot water limiter Using a hot water limiter in combination with a continuous flow water heater is not recommended D...

Page 3: ...ung siehe Seite 6 Einstellen der Warmwasserbegrenzung In Verbindung mit Durchlauferhitzern ist eine Warmwassersperre nicht zu empfehlen Ma e siehe Seite 10 Durchflussdiagramm siehe Seite 11 Wartung si...

Page 4: ...4 X 36 mm X 36 X 1 2 36 mm 3a 4 3b max 39 mm max 5 mm 5 1 2 1 2 Silicone SW 24 mm...

Page 5: ...5 6 7 2 min 9 10 11 8 SW 30 mm 17 Nm SW 22 mm SW 22 mm 2 Nm...

Page 6: ...0 3 MPa 60 C 10 C 2 1 3 4 5 6 7 4 3 1 2 3 1 2 6 x 36 C 38 C 43 C 50 C 55 C 60 C 17 x S W 4 m m S W 4 m m 5 N m SW 4 mm SW 4 mm 6...

Page 7: ...7 open ffnen close schlie en hot warm cold kalt 2 open shower ffnen Brause close shower schlie en Brause 1...

Page 8: ...8 1 3 2 1 2 1 2 Focus 31924009 31925009...

Page 9: ...9 1 3 SW 12 mm SW 12 mm 2 1 3 2 1 3 2 Focus 31941009 31942009...

Page 10: ...10 G 1 2 G 1 2 Focus 31941009 31942009 Focus 31924009 31925009...

Page 11: ...6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 1 2 2 1 2 1 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60...

Page 12: ...0 97979000 95140000 98532000 96338000 97977000 97220000 98163000 15x2 96157000 98193000 32x2 94135000 97406000 92839000 96044019 95646000 95008000 95140000 98129000 14x2 96157000 97209000 97220000 981...

Page 13: ...0 97979000 95140000 98532000 96338000 97977000 97220000 98163000 15x2 96157000 98193000 32x2 94135000 97406000 95646000 95008000 95140000 98129000 14x2 96157000 97209000 97220000 98163000 15x2 9819300...

Page 14: ...n Warranty Contact DE Reinigungsempfehlung Garantie Kontakt www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe...

Page 15: ...15...

Page 16: ...Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 01 2020 9 04605 65...

Reviews: