Install the Pop-up Drain*

Remove the plunger assembly.

Unscrew the drain outlet flange from the 

tee.

Unscrew the tailpiece from the tee.  Wrap 

the threads with plumbers’ thread tape and 

replace. 

Install the white, flexible sealing gasket to 

the flange.  Place it in the sink outlet. 

From under the sink, install the black mack 

gasket, white friction ring and retainer nut  

to the flange. Do not tighten the nut against 

the bottom of the sink at this time.

Thread the tee and tailpiece to the flange.  

The pivot must face the faucet.  If neces-

sary, turn the drain assembly.

Tighten the retainer nut.  

Place the plunger assembly in the drain. 

Install the horizontal rod so that the end 

goes through the loop in the bottom of the 

height adjuster.

Install and hand tighten the pivot ball nut.

Attach the swivel connector to the end of 

the horizontal rod.  

Attach the swivel connector to the end 

of the pull rod.   Position as desired and 

tighten with a small, flathead screwdriver.

plunger

flange

sealing gasket

mack gasket

friction ring

retainer nut

horizontal rod

height adjuster

pivot ball nut

swivel connector

pull rod

tee

tailpiece

*Drain and pull rod not included with model 

31711001.

Summary of Contents for Focus 31701001

Page 1: ...Focus 31701001 31711001 Focus 31721001 Installation Instructions Warranty...

Page 2: ...hickness 1 5 8 Flow rate 2 2 gpm max 3 8 supply hoses requires 3 8 compression fittings not included Bidet mixer 31721001 is not intended for use on a bidet with a vertical spray For best results Hans...

Page 3: ...tighten the mounting collar Attach the hoses to the supply stops with 3 8 compres sion fittings not included Use two wrenches as shown to prevent the hoses from twisting or from becoming loose Install...

Page 4: ...flange The pivot must face the faucet If neces sary turn the drain assembly Tighten the retainer nut Place the plunger assembly in the drain Install the horizontal rod so that the end goes through th...

Page 5: ...it in a safe place Remove the handle screw from the stem of the cartridge Remove the high temperature limit stop Replace the high temperature limit stop so that the pin on the cartridge is in the desi...

Page 6: ...0 3 nut 97209000 4 cartridge 92730000 5 seal 95008000 6 aerator 13085000 7 fixing set 96016000 8 connection hose 96321001 9 pull rod 96657000 10 handle screw 96059000 11 o ring 30 x 2 98186000 12 o ri...

Page 7: ...ducts Modern lavatory faucets kitchen faucets and showers consist of very different materials to comply with the needs of the market with regard to design and functionality To avoid damage and returns...

Page 8: ...orgia 30004 Attention Technical Service if required by Hansgrohe When warranty service is completed any repaired or replacement product or part will be returned to you postage prepaid EXCLUSIONS AND L...