English
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
• There must be an access door for maintenance.The
premounted filter insert must be used to ensure a
normal flow of the shower and to prevent dirt from
entering through the pipes. Dirt entering can affect the
function and/or lead to damages to the shower. Hans-
grohe will not be held liable for this type of damage.
• The mesh washer must be insert to protect the over-
head shower against incoming dirt by pipework. In-
coming dirt leads to defects or/and can damage parts
of the shower; such caused faults voids all liability and
guarantee claims.
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 12)
To adjust the hot water limiter on single lever
mixers, please see page 12. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Maintenance
(see page 16)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Cleaning
(see enclosed brochure)
Dimensions
(see page 8)
Flow diagram
(see page 11)
Spare parts
(see page 14)
Operation
(see page 13)
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,05 - 0,5 MPa
Test pressure:
1,6 MPa
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Test certificate 31523000,
31427000, 31423000:
WRAS
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!