background image

 

Safety Notes

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 
and body cleaning purposes. 

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

• The plumbing codes applicable in the respective 

countries must be oberserved.

• The drain valve must only be used as intended. It is not 

allowed to attach other objects to the drain valve, for 
example a semi-pedestal.

• If you wish to increase the water flow, the EcoSmart

®

 

(flow limiter) located behind the aerator can be 
removed.

Pressure and tightness test

• The mixer connections must be tested of tightness after 

installation.

Technical Data

Mixer with EcoSmart

®

 

(flow limiter, 5 l/min)

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar ≈ 147 PSI)
Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

60°C

Thermal disinfection: 

max. 70°C / 4 min

The product is exclusively designed for drinking water!

English

Test certificate 

(see page 9)

Cleaning 

(see page 12)

Operation 

(see page 10)

 

Hansgrohe recommends not to use 
as drinking water the first half liter of 
water drawn in the morning or after a 
prolonged period of non-use.

 

After periods of prolonged non-use, but 
at least every third day, the fittings must 
be opened with the handle in hot and 
cold position to prevent stagnation in the 
connecting lines. Let the water run until 
the water temperature is constant.

Assembly See Page 4

Dimensions 

(see page 8)

Spare parts 

(see page 11)

Installation putty (see page 5)

Adjustment 

(see page 7)

To adjust the hot water limiter.

Symbol description

Flow diagram  

(see page 9)

seal #98996000 (see page 4)

Special accessories 

(order as an 

extra)

2 (12)

Summary of Contents for Focus 100 CoolStart

Page 1: ...tion 12 SV Inneh llsf rt ckning 1 Bruksanvisning Monteringsanvisning 3 Montering 4 5 Inst llning av maxtemperatur 6 M ttskiss 7 Fl desschema 7 Hantering 8 Reservdelar 9 10 Reng ring 11 Testsigill 12 K...

Page 2: ...iter 5 l min Operating pressure max 1 MPa Recommended operating pressure 0 1 0 5 MPa Test pressure 1 6 MPa 1 MPa 10 bar 147 PSI Hot water temperature max 70 C Recommended hot water temp 60 C Thermal d...

Page 3: ...l deskontroll 5 l min Driftstryck max 1 MPa Rek driftstryck 0 1 0 5 MPa Tryck vid provtryckning 1 6 MPa 1 MPa 10 bar 147 PSI Varmvattentemperatur max 70 C Rek varmvattentemp 60 C Termisk desinfektion...

Page 4: ...4 12 Montage 1 2 1 2 1 2 98996000 5 4 3 6 SW 19 mm SW 9 mm 4 mm max 40 mm 4 mm...

Page 5: ...5 12 9 10 11 11 9 7 8 11 12...

Page 6: ...6 12 SW 22 mm 13 15 14 SW 22 mm 2 min 16...

Page 7: ...7 12 Justierung 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa...

Page 8: ...0 31604000 Focus 100 31517000 Focus 70 31733000 31604000 94139000 94139007 50100000 Focus 100 CoolStart 31509000 31621000 78 65 Focus 100 31517000 Focus 100 CoolStart 31509000 31621000 m a x 4 0 34 3...

Page 9: ...ramm Focus 70 31733000 31604000 Focus 100 31517000 Focus 100 CoolStart 31509000 31621000 2 1 EcoSmart EcoSmart 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 bar 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0...

Page 10: ...10 12 Bedienung close st nga close st nga open ppna open ppna hot varmt hot varmt cold kallt cold kallt Focus 100 CoolStart 31509000 31621000 Focus 70 31733000 31604000 Focus 100 31517000...

Page 11: ...95008000 98324000 98193000 32x2 98186000 30x2 95140000 M4x20 SW 4 mm 97209000 M 37x1 5 SW 30 mm 97406000 98532000 96338000 97209000 M 37x1 5 SW 30 mm 96657000 92604000 35x2 92730000 95008000 98750000...

Page 12: ...e com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation Hansgrohe AB Svangatn 2B 416 68 G teborg Tel...