Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from
using this product.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 37)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Dimensions
(see page 39)
Flow diagram
(see page 40)
free flow
Spare parts
(see page 41)
XXX = Colors
000 = Chrome Plated
090 = Chrome Plated/Gold Plated
130 = Polished Bronze
140 = Brushed Bronze
250 = Brushed Gold-Optic
330 = Polished Black Chrome
340 = Brushed Black Chrome
400 = White/Chrome Plated
670 = Matt Black
700 = Matt White
820 = Brushed Nickel
950 = Brushed Brass
990 = Polished Gold-Optic
Special accessories
(see page 41)
order as an extra
• extension 25 mm #13595000
• Extension Set 22 mm (when wall is not deep
enough) #15597XXX, #13597XXX,
#13593XXX
Cleaning
(see page 38)
Operation
(see page 40)
Test certificate
(see page 48)
+
Assembly
(see page 35)
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Diverter not operating
- Residue
- Clean converter / grease O-rings
- Water pressure to low
- Increase water pressure
- Diverter defective
- Exchange diverter
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
- Hot water limiter incorrectly set
- Set hot water limiter
- Crossflow
- Exchange cartridge