Thermostatic Adjustment
Temperature Limitation
The temperature is limited by the safety stop to 40°C. If
a higher temperature is required, it is possible to over ride
the safety stop by depressing the safety button.
NB.
It is recommended that for
private domestic
use
the maximum mixed water temperature be set at the
following factory set values:
Shower Mixer 43°C
Bath/Shower 43°C
Temperatures can be set by following the procedures on
page 62.
This ensures that after correct installation the
outlet temperature of the water can never exceed 43°C.
To guarantee a smooth running of the thermostatic element,
it is necessary from time to time to turn the thermostat from
total hot to total cold. The thermostatic mixer valve should
be checked annually by a qualified person to ensure
correct operation.
The mixer is fitted with check valves (page 68 pos.
94074000) and filters (page 68 pos A). If the water flow
drops the filters need to be cleaned. For that purpose
please follow the steps 1 - 11 on page 64.
Calibrating Thermostat
If the temperature reading is different to the showering
temperature, follow the steps 1 - 3 on page 62.
Technical Hotline
0 870 7701975
Summary of Contents for Ecostat E
Page 60: ...60 X SW 4 mm 5 Nm SW 5 mm 3 5 2 4 6 1 Montage 1 2 mm ...
Page 61: ...61 1 2 X 11 PuraVida 15771XXX 7 8 9 SW 2 mm 4 Nm 4 3 2 1 SW 3 mm 4 Nm ...
Page 62: ...62 SW 2 mm SW 3 mm 1 2 3 Justierung Safety Function 1 2 ...
Page 63: ...63 SW 3 mm 4 Nm z B 42 C for example 42 C SW 2 mm 4 Nm 3 4 5 6 7 8 1 2 2 1 ...
Page 64: ...64 1 2 SW 24 mm SW 2 mm SW 4 mm SW 3 mm 1 2 3 4 5 6 1 1 2 2 3 4 Wartung ...
Page 65: ...65 SW 2 mm 4 Nm SW 4 mm 5 Nm SW 24 mm 15 Nm 11 7 8 9 10 4 3 2 1 1 2 SW 3 mm 4 Nm ...
Page 66: ...66 Ecostat E 15720000 Ecostat S 15721000 PuraVida 15771XXX Metris 31573000 Maße ...
Page 67: ...67 40 C Bedienung 1 2 ...