(see page 12)
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible - thermo cartridge calcified
- Exchange thermo cartridge
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
Instantaneous heater didn't work
with thermostat
- Filters are dirty
- Clean the filter / exchange filter
- check valve hasn't moved back
- Exchange check valves
- Flow limiter in handshower isn’t
removed
- Remove flow limiter
Shower or spout dripping
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
Summary of Contents for Ecostat Comfort Series
Page 12: ...12 X 36 mm X 36 X 1 2 1 2 Silicone max 39 mm max 5 mm SW 24 mm 36 mm 1 2 3a 4 5 3b...
Page 13: ...13 97510000 SW 30 mm 17 Nm 6 7 A...
Page 14: ...14 1 2 3 4...
Page 15: ...15 z B 42 C for example 42 C 2 1 SW 3mm 1 Nm 1 2 SW 3mm 1 2 3 4 5 6...
Page 18: ...18 SW 30 mm 1 2 SW 10 mm 1 2 SW 10 mm 20 Nm rot red R d punainen r d SW 30 mm 17 Nm 1 2 3 4 5...
Page 22: ...22...
Page 23: ...23...