Maintenance
(see page 70)
To guarantee the smooth running of the
thermostat, it is necessary from time to time
to turn the thermostat from total hot to total
cold.
The mixer is equipped with non return valves.
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional regula-
tions (at least once a year).
Adjustment
(see page 63)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Safety Function
(see page 62)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Do not use silicone containing acetic acid!
Symbol description
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
anti-pollution function
The product is exclusively designed for drinking water!
6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
6
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The product is not designed to be used with steam
baths!
• The fitting must be installed, flushed and tested after
the valid norms!
Thermostatic mixer in conjunction with
combination boilers
• If fitting a hand shower remove the water limiter from
the shower.
• If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
English
6
Summary of Contents for Ecostat Comfort HQ
Page 25: ...60 96922000 MTC 96922000 42 C 65 C 72 68 66 66 64 25...
Page 27: ...60 96922000 96922000 42 65 72 68 66 66 64 27...
Page 43: ...60 96922000 96922000 42 C 65 C 72 68 66 66 64 43...
Page 55: ...60 96922000 96922000 42 C 65 C 72 68 66 66 64 55...
Page 58: ...60 64 66 66 68 72 96922000 96922000 65 C 42 C 58...
Page 59: ...U U U U U 97510000 1 0 1 0 5 1 6 1 10 147 PSI 80 C 65 C 4 70 C 62 42 63 70 DIN EN 1717 59...
Page 60: ...60 5 1 3b 2 4 3a 1 2 1 2 Silicone 1 2 min 34 mm max 39 mm max 5 mm SW 24 mm...
Page 61: ...61 6 7 SW 30 mm 17 Nm...
Page 62: ...62 z B 42 C for example 42 C 4 3 1 2 5 SW 3 mm 2 1 SW 3 mm 1 Nm...
Page 63: ...63 1 4 2 3...
Page 70: ...70 1 2 3 SW 30 mm 1 2 SW 10 mm 4 5 SW 10 mm 20 Nm 6 1 2 SW 30 mm 17 Nm...
Page 71: ...71...