Spare parts
(see page 22)
English
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Filters are dirty (96922000)
-
Clean filter in front of the mixer
and on the MTC-thermo cartridge
(96922000)
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or
leaking
-
Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
Shower or spout dripping
-
Dirt or sedimentation on valve seat,
shut-off unit damaged
-
Clean or exchange shut-off unit
Instantaneous heater didn’t work
with thermostat
-
Non return valve hasn’t moved
back
-
Exchange non return valves
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Filters are dirty
-
Clean the filter / exchange filter
Assembly see page 14
Flow diagram
(see page 20)
Shower
Bath tub
5
Summary of Contents for Ecostat Comfort 13119000
Page 14: ...14 5 1 3b 2 4 3a 1 2 1 2 Silicone 1 2 min 32 mm max 37 mm max 5 mm SW 24 mm ...
Page 15: ...15 6 7 SW 30 mm 17 Nm 97510000 ...
Page 16: ...16 z B 42 C for example 42 C 4 3 1 2 SW 2 5 mm 2 Nm 5 SW 2 5 mm 2 1 ...
Page 17: ...17 1 4 2 3 ...
Page 21: ...68 1 2 3 SW 30 mm 1 2 SW 10 mm 4 5 SW 10 mm 20 Nm 6 1 2 SW 30 mm 17 Nm ...
Page 23: ...23 ...