3
3 (16)
English
Assembly
(See Page 6)
Troubleshooting
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Filters are dirty (#97367000)
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
(#97367000)
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 60 ºC
Temperature regulation not possible - thermo cartridge calcified
- Exchange thermo cartridge
Shower or spout dripping
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
Summary of Contents for Ecostat 1001 CL 13218000
Page 7: ...7 3 mm 3 mm 1 3 4 2 5 6 7 16...
Page 8: ...8 1 2 3 mm for example 42 C till exempel 42 C 1 2 3 mm 1 4 6 5 2 3 8 16...
Page 9: ...9 3 mm for example 10 l min till exempel 10 l min SW 3 mm 1 2 4 3 5 6 9 16...
Page 10: ...10 6 mm 23 mm 6 mm 1 2 1 2 3 4 5 6 10 16...
Page 12: ...12 open ppna hot varmt cold kallt close st nga Ecostat 1001 CL 13218000 1 2 1 40 C 2 12 16...