Safety Notes

 

6

Gloves should be worn during installation to 

prevent crushing and cutting injuries.

 

6

Children as well as adults with physical, mental 

and/or sensoric impairments must not use this 

product without proper supervision. Persons 

under the influence of alcohol or drugs are 

prohibited from using this product.

 

6

Do not allow the streams of the shower touch 

sensitive body parts (such as your eyes). An 

adequate distance must be kept between the 

shower and you.

 

6

The product may not be used as a holding 

handle. A separate handle must be installed.

 

6

The shower system may only be used for bathing, 

hygienic and body cleaning purposes.

 

6

Shower hoses are only suitable for a connection 

from the shower to the fitting. Never fit a shut-off 

device between the fitting and the hose.

Installation Instructions

•  Prior to installation, inspect the product for 

transport damages. After it has been installed, no 

transport or surface damage will be honoured.

•  The pipes and the fixture must be installed, 

flushed and tested as per the applicable 

standards.

•  The plumbing codes applicable in the respective 

countries must be observed.

•  In order to meet the requirements of the 

AS / NZS 2845.1, the enclosed backflow pre-

venter must be installed. 

•  The mesh washer must be insert to protect the 

shower against incoming dirt by pipework. 

Incoming dirt leads to defects or/and can dam-

age parts of the shower; such caused faults voids 

all liability and guarantee claims.

•  The wall bar must be mounted stress relieved!
•  Optimal functioning is only guaranteed with the 

combination of Hansgrohe hand showers and 

Hansgrohe shower hoses.

Technical Data

Operating pressure:  

max. 0,6 MPa

Recommended operating pressure:   0,1 - 0,4 MPa

(1 MPa = 10 bar = 147 PSI)

Hot water temperature:  

max. 60°C

Thermal disinfection: max.  

70°C / 4 min

•  The product is exclusively designed for drinking 

water!

Symbol description

Do not use silicone containing acetic 

acid!

Dimensions 

(see page 13)

Flow Diagram 

(see page 13)

Overhead shower 

Hand shower

Operation 

(see page 7)

To empty the overhead shower after use, 

hold it in a slightly inclined position

Cleaning 

(see page 10)

Maintenance 

(see page 9)

This product is equipped with check 

valves. The check valves must be checked 

regularly according to DIN EN 1717 in 

accordance with national or regional 

regulations (at least once a year).

Replacement parts 

(see page 17)

Assembly see page 4

English

Summary of Contents for Croma Select E 26743003

Page 1: ...EN Instructions for use Assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 3 Showerpipe 240 EcoSmart 26742003 Croma Select E 26743003 Showerpipe 27732003 Croma Select S 26744003...

Page 2: ...e in the respective countries must be observed In order to meet the requirements of the AS NZS 2845 1 the enclosed backflow pre venter must be installed The mesh washer must be insert to protect the s...

Page 3: ...er Montage des Produktes durch qualifi ziertes Fachpersonal ist darauf zu achten dass die Befestigungsfl che im gesamten Bereich der Befestigung plan ist keine vorstehenden Fugen oder Fliesenversatz d...

Page 4: ...4 20 20 1 2 3 4 1 inch 5 2 2 1 1 G 1 2...

Page 5: ...5 6 7 8 9 6 mm 6 mm silicone silicone silicone 1 2 2 3 1 2 3 1 1 2 2 8 mm 1 inch 11 10 1...

Page 6: ...6 13 14 15 1 2 3 8 mm 17 mm 10 Nm 2 5 mm 6 Nm 2 5 mm 6 Nm 12 1 2...

Page 7: ...7 1 2...

Page 8: ...8 2b 2a 1 2 1...

Page 9: ...9 1 2 3 4 5...

Page 10: ...10 50 mm 3 mm 2 Nm 3 mm 17 mm 1 2 3 4 5 6...

Page 11: ...en toute simplicit les d p ts form s sur les buses lastiques en silicone s liminent par un simple passage de la main F cil aseo La cal se puede retirar sencillamente frotando con los dedos de las tob...

Page 12: ...limpeza Garantia Contacto PL Zalecenie dotycz ce piel gnacji Gwarancja Kontakt CS Doporu en k ist n Z ruka Kontakt SK Odpor ania pre istenie Z ruka Kontakt ZH RU HU Tiszt t si tan csok Garancia rintk...

Page 13: ...2 15 15 207 Showerpipe 240 EcoSmart 26742003 1 2 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 M...

Page 14: ...26 187 8 9 6 230 Croma Select E 26743003 1 2 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0...

Page 15: ...26 26 187 8 9 6 230 Croma Select S 26744003 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0...

Page 16: ...16 Showerpipe 27732003 6 0 0 8 0 8 0 388 63 10 37 22 0 5 10 15 20 25 30 6 5 4 3 2 1 Flow rate L min Water Pressure in Bars 1 1 2 2...

Page 17: ...17 Showerpipe 240 EcoSmart 26742003 98058000 95160000 95333000 98058000 94146000 98716000 92146000 25x2 5 98472000 65x2 28276000 95687000 95690000 95689000 93807000...

Page 18: ...18 Croma Select E 26743003 98058000 95160000 95333000 98058000 94146000 98716000 92146000 25x2 5 98472000 65x2 28276000 95687000 95690000 95689000 93807000...

Page 19: ...19 Croma Select S 26744003 98058000 95160000 95333000 98058000 94146000 98716000 92146000 25x2 5 98472000 65x2 28276000 95687000 95690000 95689000 93807000...

Page 20: ...7761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 11 2019 9 06674 31 98058000 95160000 95333000 98716000 92146000 25x2 5 98472000...