background image

 

Safety Notes

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The arm of the shower head is intended only to hold 
the shower head. Do not load it down with other 
objects!

 

Children as well as adults with physical, mental and/
or sensoric impairments must not use this product 
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using 
this product.

 

Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate 
distance must be kept between the shower and you.

 

The product may not be used as a holding handle. A 
separate handle must be installed.

 

The product may only be used for bathing, hygienic 
and body cleaning purposes.

 

The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

• The installation dimensions stated in these installation 

instructions are ideal for people of approximately 
1700 mm in body height. The dimensions can be al-
tered if required. In this case, pay attention to the fact 
that a change of installation height will also change 
the minimum height, and that the altered mounting 
dimensions must be taken into consideration.

• During installation of the product by qualified trained 

personnel, make sure that the entire fastening surface 
is even and smooth (no protruding seams or tile 
offset), that the finish of the wall is suitable to apply the 
product and has no weak points.

English

• The mesh washer must be insert to protect the over-

head shower against incoming dirt by pipework. In-
coming dirt leads to defects or/and can damage parts 
of the shower; such caused faults voids all liability and 
guarantee claims.

• If required, the bottom part of the pipe between the 

fixture and the shower head can be shortened with a 
fine-toothed saw.

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure 

0,15 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Centre distance: 

150 ± 12  mm

Connections G 1/2: 

cold right - hot left

Thermal disinfection: 

max. 70°C / 4 min

• Safety against backflow

• The product is exclusively designed for drinking water!

4

Summary of Contents for Croma 160 Showerpipe27245000

Page 1: ...Croma 160 Showerpipe 27245000 ZH 2 EN Instructions for use assembly instructions 4...

Page 2: ...1700 mm 1 MPa 0 15 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 70 C 65 C 150 12 mm G 1 2 70 C 4 2...

Page 3: ...18 11 11 12 14 6 95163000 18 10 3...

Page 4: ...ation dimensions stated in these installation instructions are ideal for people of approximately 1700 mm in body height The dimensions can be al tered if required In this case pay attention to the fac...

Page 5: ...ter seal dirty Clean filter seal between shower and hose Mixer stiff Cartridge defective calcified Exchange cartridge Mixer dripping Cartridge defective Exchange cartridge Hot water temperature too lo...

Page 6: ...6 Montage 1 2 2 1 2 1 36 mm 3a 3b 95163000 max 39 mm max 5 mm...

Page 7: ...7 Montage 4 5 6 7 SW 8 mm 1 2 SW 8 mm 8...

Page 8: ...8 Montage 1 6 mm 2 9 Silicone 10 3 12 11 1 2 3 max 875 mm...

Page 9: ...9 2 N r 1 0 4 7 6 2 2 0 A r m a t u r e n f e t t G r e a s e 1 13 95659000 94246000 SW 17 mm 14 10 Nm 15 16 94246000...

Page 10: ...60 C 10 C 0 3 MPa 2 1 3 4 5 6 7 4 3 1 2 3 1 2 6 x 36 C 38 C 43 C 50 C 55 C 60 C 17 x 4 m m 4 m m 5 N m 4 mm 4 mm 10...

Page 11: ...12 min 25 1918 1918 2020 1920 2120 2018 1818 1018 900 1000 800 235 22 G1 2 G1 2 68 432 41 347 63 160 26 26 725 875 168 76 65 23 1820 1820 1920 1920 1720 1720 1 0 0 50 83 Croma 180 Showerpipe 27245000...

Page 12: ...12 Bedienung open close hot 2 1 open...

Page 13: ...13 Bedienung 1 2a 2b 1 2 cold Croma 100 Vario 28537007...

Page 14: ...14 Reinigung QuickClean QuickClean Hansgrohe Hansgrohe www hansgrohe int com guarantee QUICK CLEAN...

Page 15: ...Never use cleaning materials which contain hydrochloric acid formic acid chlorine pale lye or acetic acid as they cause considerable damage Phosphorus acidic cleaners are only conditionally applicabl...

Page 16: ...16 Reinigung max 10 min 20 mm 4 3 1 min 5 1 2 94246000...

Page 17: ...17 93339000 94246000 Reinigung 3 4 1 min 5 1 2 6...

Page 18: ...0 98131000 15x2 5 96467000 97220000 98163000 15x2 97981000 97979000 98058000 98382000 12x2 25 92730000 95008000 98193000 32x2 97406000 96338000 32096000 28537007 96179000 95163000 94140000 SW 24 mm 96...

Page 19: ...19...

Page 20: ...20 Pr fzeichen Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 03 2018 9 02295 07...

Reviews: