Assembly see page 31
Test certificate
(see page 36)
Special accessories
(order as an extra)
spray body #92341000 (recommended at operating pressure <
0,15 MPa)
Spare parts
(see page 36)
XXX = Colors
000 = chrome plated
450 = white
Maintenance
(see page 33)
The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
Operation
(see page 33)
• As with all other fittings, do not use the first half liter as drinking water
in the mornings or after standstill of > 4 h. In subtropical and tropical
countries, the first half liter of water must generally be discarded.
(For more information, contact your local environmental or health
authorities.)
• After the fitting has been out of use for more than three days (for
example during vacation), discard the residual water from the outlet
to prevent moscitoe breeding.
• When the water is stagnant over a prolonged period of time, dirt
particles from the environment will get into the water. For this reason,
the entire glass spout must be cleaned in regular intervals (at least
once per week), and daily in subtropical and tropical countries.
• The glass spout must be treated with care.
Cleaning
(see page 34 and enclosed brochure)
Flow diagram
(see page 32)
Dimensions
(see page 32)
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
There may be hot water in the glass spout. Risk of scalding.
Dust and other solid particles may deposit in the open spout on or in the water.
Detergents or other harmful liquids may mix with the stagnant water.
The water may go bad due to other external influences.
Because of the open design of the water spout, contamination from outside may
enter the unit.
A damaged glass spout must be replaced. Risk of injury.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• After it has been installed, no transport or surface damage will be honoured.
• The product is only suitable for private use. It is unsuitable for use in semi-public
and public areas.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• Please pay attention to the fact that the mixer is equipped with a laminar spray.
This enhances the natural aspects of water as element of life.
As this laminar spray does not contain any air, we recommend the use of very
deep washbasins to reduce splashing.
For further recommendations please consult the Axor Mixer/ Wash Basin Matrix.
To reduce splashing, you can also change the point where the water jet hits the
washbasin. To do so, swivel the spout or loosen the spray former to disable the
vortex. (see page 31 Fig. A - C)
• The drain valve must only be used as intended. It is not allowed to attach other
objects to the drain valve, for example a semi-pedestal.
Technical Data
This mixer series-produced with EcoSmart
®
(flow limiter)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,15 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English