Assembly see page 31
Spare parts
(see page 36)
Flow diagram
(see page 35)
Mono spray
Normal spray
Dimensions
(see page 35)
Maintenance
(see page 34)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Operation
(see page 34)
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The product may not be used as a holding handle. A
separate handle must be installed.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Cleaning
(see enclosed brochure)
4
Test certificate
(see page 34)