Assembly see page 60
Fault
Cause
Remedy
Insufficient water
–Supply pressure inadequate
–Check water pressure (If a pump
has been installed check to see if
the pump is working).
–Filters are dirty
–Clean filter in front of the mixer
and on the MTC-thermo cartridge
–Shower filter seal dirty
–Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
–Backflow preventers dirty or leak-
ing
–Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
–Thermostat has not been adjusted
–Adjust thermostat
–Hot water temperature too low
–Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
–thermo cartridge calcified
–Exchange thermo cartridge
Shower or spout dripping
–Dirt or sedimentation on valve seat,
shut-off unit damaged
–Clean or exchange shut-off unit
Instantaneous heater didn’t work
with thermostat
–Flow limiter in handshower isn’t
removed
–Remove flow limiter
–Filters are dirty
–Clean the filter / exchange filter
–Non return valve hasn’t moved
back
–Exchange non return valves
Cleaning
(see enclosed brochure)
Spare parts
(see page 71)
English
7
Summary of Contents for AXOR Starck Organic 12410000
Page 60: ...60 1 1 2 2 Silicone 1 2 150 12 SW 27 mm 3 4 5 6 38 38 ...
Page 61: ...61 7 8 9 10 Ø 8 mm Silicone SW 10 mm SW 3 mm SW 3 mm 11 12 2 1 2 SW 3 mm 2 1 ...
Page 62: ...62 13 14 15 16 2 2 2 1 1 1 SW 3 mm 3 Nm SW 3 mm 3 Nm ...
Page 63: ...63 z B 42 C for example 42 C 2 1 SW 3 mm SW 3 mm 1 Nm 1 2 3 4 5 6 ...
Page 64: ...64 1 4 2 3 ...
Page 65: ...65 1 2 SW 3 mm 3 Nm 1 2 1 SW 3 mm 2 3 4 5 6 SW 22 mm SW 22 mm 4 Nm ...
Page 66: ...66 2 1 SW 3 mm 3 Nm 2 1 SW 3 mm 3 Nm 7 8 9 10 ...
Page 69: ...69 Starck Organic 12410000 Starck Organic 12602000 ...
Page 70: ...70 Starck Organic 12410000 Starck Organic 12602000 2 1 ...