6
Electrician
The installation and test work must be performed by an
authorized electrician under consideration of DIN VDE
0100 part 701 / IEC 60364-7-701.
Electrical connection
Voltage supply: 100–240 V/N/PE/50–60Hz
The transformer must not be installed in protection zones
0, 1 or 2.
The transformer must be installed inside the wall in
a > Ø 60 mm socket. This socket inside the wall is
connected to the light via an empty conduit EN 20. You
need tools to access the flush-type box. (see page 62
Fig. 1)
Residual current protection system
The circuit must be protected via a ground fault protector
(RCD / FI) with a measured differential current of ≤ 30
mA.
The proper function of this fusing/protection must be
checked at regular intervals.
Any work may only be carried out in a de-energized
state. Here, the voltage supply must be safely separated
via the main switch or mains plugs.
Consistency of installation surface
Please also make sure that the installation surface
is even. If there are deep ridges or offset tiles, it is
necessary to even out this unevenness using silicone.
Assembly
(see page 61)
Beware of dangerous electrical
current
Do not use silicone that contains acedic
acid.
Symbol description
English
Safety Notes
Electrical installation
Intended Use
Light
The light type 40871000 is only suited for use in interior
rooms, baths and showers in zones type 1 and 2 as
well as outside aforementioned zones as per DIN VDE
0100 part 701 / IEC 60364-7-701 and must only be
powered with SELV 12 V DC.
transformer
The voltage supply from the 12 V DC SELV must only be
fed via the included transformer type 19769610. The
transformer must be installed safe from outside contact
outside the zones 0, 1 and 2 in a flush-type box to be
provided by the customer.
The mains voltage of 100 - 240 V AC 50 - 60 Hz must
be supplied via a existing shutoff device (switch) as well
as a ground fault protector (RCD / FI) with a measured
differential current of ≤ 30 mA.
Read the installation instructions
Spare parts
(see page 60)
Dimensions
(see page 60)
Product description
The Axor Starck ShowerCollection light type 40871000
is a 12 V 3 W IP X5 built-in LED and is used to illuminate
baths and showers.
The transformer type 19769610 is only suited for the
voltage supply of the light type 40871000.
A different or excessive use is considered non-intended.
The user/operator bears the sole risk. The intended use
includes the adherence to the operating instructions
and the observance of the inspection and maintenance
guidelines.
The manufacturer/seller of this light does not assume
any responsibility for injuries or damage that may be
caused by improper installation or non-intended use.
Important notice
Repair
(see page 64)
Installation Instructions
Summary of Contents for AXOR Starck 40871000
Page 60: ...60 95587000 97663000 96338000 95465000 95585000 3 6 W 0 3 A 3200 K 95586000 2 m m...
Page 63: ...63 2 mm 1 Nm 8 Silikon 6 7 9 5 Nm 1 2 1 2...
Page 64: ...64 2 mm 1 2 3 3 4 5 6 2 7 mm 3 1 2 1 7 mm...
Page 65: ...65 3 7 1 2 2 mm 1 Nm 10 Silikon 8 9 11 5 Nm 1 2 1 2...
Page 66: ......
Page 67: ......