Assembly see page 60
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Regulator filter dirty
-
Clean filters
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or
leaking
-
Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
Temperature regulator dirty or
calcified
-
Clean temperature regulator,
exchange if necessary
-
For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
-
change connections
Safety stop button not operating
-
Spring defective
-
Button calcified
-
Clean spring and/or button,
exchange if necessary
English
Test certificate
(see page 68)
Cleaning
see enclosed brochure.
Operation
(see page 66)
Spare parts
(see page 67)
Dimensions
(see page 68)
Special information for UK
(see page 69)
7
Summary of Contents for Axor Starck 10755000
Page 25: ...60 42 C 65 C 180 68 66 67 68 25...
Page 27: ...60 42 65 180 68 66 67 68 27...
Page 43: ...60 42 C 65 C 180 68 66 67 68 43...
Page 55: ...60 42 C 65 C 180 68 66 67 68 55...
Page 58: ...60 42 65 180 68 66 67 68 58...
Page 60: ...60 27 mm 1 2 3 4 Silicon 17 mm 6 5 24 mm 15 2 Nm 10754180...
Page 61: ...61 11 12 8 2 mm 7 3 mm 4 1 Nm 2 1 10 9...
Page 62: ...62 1 2 2 mm 3 mm 1 3 2 1 2 2 mm 2 mm 1 2 4 1 Nm...
Page 63: ...63 4 3 6 1 2 5 3 mm 1 2 7 8 1 2 2 mm 4 1 Nm...
Page 64: ...64 2 3 4 1 1 2 3 6 5 SW 24 mm 3 mm 2 mm...
Page 65: ...65 8 9 10 7 3 11 2 mm 3 mm 4 1 Nm SW 24 mm 15 2 Nm...
Page 66: ...66 1 40 C 2...
Page 68: ...68 PA IX DVGW SVGW ACS WRAS KIWA ETA 10755000 X X X Starck 10755000...
Page 75: ...75...