0 5
EN
A S S E M B L Y (see page 06 )
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Supply pressure inadequate
⁄ Check water pressure (If a pump has
been installed check to see if the pump
is working).
⁄ Regulator filter dirty
⁄ Clean filter in front of the mixer and on
the MTC-thermo cartridge
⁄ Shower filter seal dirty
⁄ Clean filter seal between shower and
hose
⁄ Crossflow, hot water being forced into
cold water pipe, or vice versa, when
mixer is closed
⁄ Backflow preventers dirty or leaking
⁄ Clean backflow preventers, exchange
if necessary
⁄ Spout temperature does not
correspond with temperature set
⁄ Thermostat has not been adjusted
⁄ Adjust thermostat
⁄ Hot water temperature too low
⁄ Increase hot water temperature to
42 ºC to 60 ºC
⁄ Temperature regulation not possible
⁄ thermo cartridge calcified
⁄ Exchange thermo cartridge
⁄ For new installations: basic body incor-
rectly connected (should be: cold right,
hot left) or installed with 180º rotation
⁄ Install function block turned through
180º
⁄ Safety stop button not operating
⁄ Spring defective
⁄ Button calcified
⁄ Clean spring and⁄or button, exchange
if necessary
⁄ Valve stiff
⁄ Select stop valve DN9 damaged
⁄ Exchange Select stop valve DN9
⁄ Shower or spout dripping
⁄ Select stop valve DN9 damaged
⁄ Exchange Select stop valve DN9
⁄ Pushbutton cannot be actuated or is
without function
⁄ Safety guard of isolating valve has not
been removed
⁄ Remove safety guard from isolating
valve
⁄ Pushbutton is jammed or stiff
⁄ Seal needs greasing
⁄ Grease the seal
⁄ Pushbutton does not snap in
⁄ Select Adapter incorrectly trimmed
⁄ Trim and mount Select Adapter accord-
ing to Fig. 7 (see page 07 + 10 )
⁄ First, fully press the pushbutton down
into the rosette; then, mount the rosette
Summary of Contents for AXOR ShowerSelect Soft Cube 36707 7 Series
Page 3: ...0 3 ZH 06 42 C 60 C 180 180 Select DN9 Select DN9 Select DN9 Select DN9 7 07 10...
Page 7: ...0 7 SW 4 mm 1 2 0 mm 0 mm 7 8 9 10...
Page 8: ...0 8 X 11 X 1 2 mm 0 1 Nm SW 10 mm 2 Nm 11 12 13 14 15 16...
Page 9: ...0 9 C 40 1 2 40 C 1 2 C 40 1 2 2 1 1 2 17 18 19 20 21 22...
Page 11: ...11 40 C max 5 25 0 SW 4 mm 5 Nm SW 4 mm 7 mm 1 2 A B C D...
Page 12: ...1 2 42 C for example 42 C 2 1 1 2 SW 3 mm 1 2 40 C 40 C 40 C 40 C 1 CLICK 2 1 2 3 4 1 2 3...
Page 13: ...1 3 2 1 C 40 1 2 40 C 1 2 CLICK 1 2 SW 3 mm 1 Nm 5 6 7 8 9...
Page 14: ...1 4 SW 27 mm C 40 2 3 1 SW 4 mm 1 3 5 2 4 6...
Page 15: ...1 5 red SW 4 mm 5 Nm SW 27 mm 8 Nm 40 C 40 C CLICK 2 1 3 0 1 Nm 7 9 11 8 10 12...
Page 16: ...1 6 40 C 1 2 40 C 40 C 40 C 40 C...
Page 20: ...2 0 AXOR AXOR www hansgrohe int com guarantee Q U I C K C L E A N QuickClean...
Page 22: ...2 2...
Page 23: ...2 3...