Assembly see page 32
Cleaning
(see page 39) and en-
closed brochure
If the waterflow drops, clean the filter
located between hose and handspray.
Operation
(see page 37)
• Do not rotate the spout further than 360º
or damage to the hose will result.
• Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
Spare parts
(see page 38)
XXX = Colors
000 = chrome plated
800 = stainless steel optic
Flow diagram
(see page 31)
Rate of flow Normal spray
Rate of flow Regular
Dimensions
(see page 31)
Do not use silicone containing acetic acid!
Adjustment
(see page 36)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Maintenance
(see page 39)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
4