Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The product is not designed to be used with steam
baths!
Thermostatic mixer in conjunction with
combination boilers
• If fitting a hand shower remove the water limiter from
the shower.
• In case of problems with the continuous water heater
or of greatly varying water pressures, you must install
the water limiter (comprised in the delivery, article
number 97510000) in the cold water supply.
English
Maintenance
(see page 65)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
• The mixer is equipped with check valves.
The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
Do not use silicone containing acetic acid!
Symbol description
Adjustment
(see page 62)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Safety Function
(see page 63)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Centre distance:
150 ± 12 mm
Connections G 1/2:
cold right - hot left
Safety against backflow
The product is exclusively designed for drinking water!
6
Summary of Contents for AXOR Citterio E 34435000
Page 60: ...60 Montage 5 1 3b 2 4 3a 1 2 1 2 Silicone 1 2 min 34 mm max 39 mm max 5 mm SW 24 mm ...
Page 61: ...61 Montage 6 7 SW 30 mm 17 Nm 8 10 9 SW 22 mm 2 min SW 22 mm 2 Nm ...
Page 62: ...62 Justierung 1 4 2 3 ...
Page 63: ...63 Safety Function SW 2 5 mm SW 2 5 mm 1 Nm z B 42 C for example 42 C 4 3 1 2 5 6 1 2 2 1 1 ...
Page 65: ...65 Wartung 1 2 3 SW 30 mm 1 2 SW 10 mm 4 5 SW 10 mm 20 Nm 6 1 2 SW 30 mm 17 Nm ...