Assembly see page 32
Fault
Cause
Remedy
Insufficient water
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
-
Non return valve hasn‘t moved back
-
Exchange non return valves
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low
-
Hot water limiter incorrectly set
-
Set hot water limiter
Instantaneous heater didn’t work
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Filters are dirty
-
Clean the filter / exchange filter
-
Non return valve hasn‘t moved back
-
Exchange non return valves
Cleaning
see enclosed brochure.
Test certificate
(see page 40
Spare parts
(see page 38)
XXX
= Colors
000 = chrome plated
090 = chrome plated/gold plated
Flow diagram
(see page 37)
Dimensions
(see page 37)
Operation
(see page 36)
Maintenance
(see page 35)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional regula-
tions (at least once a year).
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 34. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages.After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
• Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heat-
ers if the flow pressure is at least 0,15 MPa.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150 ±12 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
anti-pollution function
The product is exclusively designed for drinking water!
English