4
SafetyNotes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
InstallationInstructions
• Prior to installation, inspect the product for transport
damages.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
®
(flow limiter) located behind the aerator can be
removed.
TechnicalData
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
English
Cleaning
(see enclosed brochure)
Operation
(see page 36)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Spareparts
(see page 37)
XXX
= Colors
000 = chrome plated
090 = chrome plated/gold plated
Dimensions
(see page 35)
Do not use silicone containing acetic acid!
special tool #58085000
Installation putty
Symboldescription
Flowdiagram
(see page 35)
with EcoSmart
®
without EcoSmart
®
Assemblyseepage31
Specialaccessories
(order as an
extra)