SafetyNotes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
InstallationInstructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
®
(flow limiter) located behind the aerator can be
removed.
TechnicalData
Thismixerseries-producedwithEcoSmart
®
(flow
limiter)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Cleaning
see enclosed brochure
Operation
(see page 36)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Spareparts
(see page 35)
Assemblyseepage31
Dimensions
(see page 34)
Do not use silicone containing acetic acid!
Specialaccessories
(order as an
extra)
special tool #58085000
Installation putty
Symboldescription
Flowdiagram
(see page 34)
with EcoSmart
®
without EcoSmart
®
Testcertificate
(see page 36)
4