The fitting must installed, flushed and tested
after the valid norms!
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in posi
tion on the sink.
3. Slip the plastic washer, the slide washer, the metall
washer and collar nut over the hose and threaded
base and tighten the collar nut by hand. If there is
not enough space, please use only the slide washer
and the metall without the plastic washer.
4. Tighten screws.
5. Connect the connecting hose / supply pipes to the
angle valves;
cold right hot left.
Large differences in pressure between the hot and cold
water supply should be balanced.
Operation
The mixer is activated by pulling the lever handle.
Turning to the left = cooler water,
turning to the right = warmer water.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0.1 0.5 MPa
Test pressure:
1.6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80° C
Recommended hot water temp.:
65° C
Rate of flow by 0.3 MPa:
13 l/min
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0.15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
English
Spare parts
(see page 3)
1
llever head
97400000
1.1 screw cover
96338000
2
flange
96468000
3
nut
96461000
4
cartridge cpl.
92730000
5
aerator cpl.
13913000
6
fixation cpl.
95049000
7
connection hose 900 mm
98785000
8
spout cpl.
92830000
9
sealing set
92646000
Summary of Contents for Adoro 14862000
Page 1: ...Montageanleitung Adoro 14862000 ...
Page 3: ... 1 1 1 2 3 4 5 6 7 8 9 ...