Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The product is not designed to be used with steam
baths!
Assembly
(see page 6)
Pressure and permeability test
The connections of the thermostatic mixer should be
tested regular after installation.
English
ECOSTOP
(see page 9)
Safety Function
(see page 8)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Do not use silicone containing acetic acid!
Symbol description
Maintenance
(see page 10)
• The mixer is equipped with check valves.
The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
Adjustment
(see page 7)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar ≈ 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
160 mm
Connections M 26x1,5:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
Safety against backflow
The product is exclusively designed for drinking water!
2 (16)
Summary of Contents for 8351037
Page 7: ...7 16 Justierung 1 3 4 2 5 6 3 mm 3 mm ...
Page 8: ...8 16 Safety Function 1 4 6 5 1 2 3 mm for example 42 C till exempel 42 C 2 3 1 2 3 mm ...
Page 9: ...9 16 ECOSTOP 1 2 4 3 5 6 3 mm for example 10 l min till exempel 10 l min SW 3 mm ...
Page 10: ...10 16 Wartung 6 mm 23 mm 6 mm 1 2 1 2 3 4 5 6 ...