22 (12)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The drain valve must only be used as intended. It is
not allowed to attach other objects to the drain
valve, for example a semi-pedestal.
• If you wish to increase the water flow, the EcoSmart
®
(flow limiter) located behind the aerator can be
removed.
Pressure and tightness test
• The mixer connections must be tested of tightness
after installation.
Technical Data
Mixer with EcoSmart
®
(flow limiter, 5 l/min)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar ≈ 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Adjustment
(see page 6)
To adjust the hot water limiter.
Dimensions
(see page 7)
Flow diagram
(see page 7)
Operation
(see page 8)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
After periods of prolonged non-use, but at least
every third day, the fittings must be opened with the
handle in hot and cold position to prevent stagnation
in the connecting lines. Let the water run until the
water temperature is constant.
Spare parts
(see page 9)
Special accessories
(order as an extra)
seal #98996000 (see page 4)
Cleaning
(see page 10)
Test certificate
(see page 11)
English
Assembly
(See Page 4)