*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
* Vous devez connaître et respecter tous les codes de plomberie locaux applicables pour le réglage de la température du
chauffe-eau.
*Debe conocer y cumplir todos los códigos locales aplicables para ajustar la temperatura del calentador de agua.
Recommended water pres-
sure
Pression d’eau recommandée Presión recomendada en
servicio
15 - 75 psi
Max. water pressure
Pression d’eau maximum
Presión en servicio max.
15 psi
Recommended hot water
temp.
Température recommandée
d'eau chaude
Temperatura recomendada
del agua caliente
120°-10°F*
Max. hot water temp
Température maximum d'eau
chaude
Temperatura del agua
caliente max.
176°F*
Flow rate - bodysprays
Capacité nominale - douches
latérales
Caudal máximo - duchas
laterales
2.5 gpm
Flow rate - handshower
Capacité nominale -
douchette
Caudal máximo - teleducha 2.5 gpm
Technical Information / Données techniques / Datos tecnicos
Installation Considerations
For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
Please read over these instructions thoroughly
before beginning installation. Make sure that
you have all tools and supplies needed to com-
plete the installation.
This trim requires iBox Plus Universal rough valve
01850181 (not included). For correct operation
of the thermostatic mixing valve, the hot supply
must be on the left and the cold supply must be
on the right.
Flush the hot and cold supply lines thoroughly
prior to installation of the function block. Dam-
age to the thermostatic cartridge caused by
debris is not covered under the warranty.
•
•
•
•
Protection against backflow is provided by check
valves.
To prevent scald injury, the maximum output
temperature of the shower valve should be no
higher than 120°F. In Massachusetts, the maxi-
mum output temperature of the shower valve can
be no higher than 112°F.
Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product
in a safe place. The receipt is required should it
be necessary to request warranty parts.
•
•
•