Assembly see page 32
Test certificate
(see page 40)
Potential equalisation
(see page 33)
Spare parts
(see page 36)
Cleaning
(see page 35) and en-
closed brochure
Flow diagram
(see page 31)
Dimensions
(see page 31)
Do not use silicone containing acetic acid!
Symbol description
Technical Data
Operating pressure:
max. 0,6 MPa
Recommended operating pressure:
0,17 – 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
6
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
6
Pursuant to DIN VDE 0100 T 701 section
701.415.2, the overhead shower must be connected
to potential bonding.
Installation Instructions
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
English
4
Summary of Contents for 26472000
Page 3: ...31 260 2 6 0 214 Raindance 26472000 Raindance 26481000 260 240 6 0 m i n...
Page 4: ...32 5 1 2 3 4 6 1 2 SW 13 mm 26471180 SW 13 mm 58 mm...
Page 5: ...33 8 10 9 11 12 7 SW 2 5 mm 2 Nm SW 24 mm SW 10 mm 4 mm 1 2...
Page 6: ...34 13 NO...
Page 7: ...35 3 5 4 SW 4 mm 2 Nm SW 2 5 mm 2 Nm 1 2 SW 2 5 mm SW 4 mm 1 1 2 2...
Page 8: ...36 98419000 7x2 92333000 95795000 92804000 Raindance 26472000...
Page 9: ...37 92333000 92804000 98419000 7x2 95795000 98894000 9 l min Raindance 26481000...