Hans Grohe 06630XX0 Installation Instructions Manual Download Page 2

Technical Information

Recommended water pressure 

45-80 psi 

Max. water pressure 

145 psi

Recommended hot water temp. 

10° - 140° F*

Max. hot water temp 

165°F*

Hole size in mounting surface 
 

valves 

1¼"

 

spout 

1⅜"

 

spout retaining pin 

³⁄₁₆"

Max. mounting surface depth 

1⁹⁄₁₆"

Max flow rate 

10 gpm

*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. 

3-Hole Roman Tub Rough
06607000

Installation Considerations

For best results, this unit should be installed by a licensed, professional plumber.

Large differences in pressure between the hot and cold supplies should be balanced.

The included connecting tubes are type “K” copper tubing.  If an installation different from the one 
shown here is desired, the plumber may provide his own copper tubing.

To insure proper fit of the trim, this valve must be installed after the mounting surface is finished and 
made watertight.

This valve requires ½" hot and cold supply lines (not included)

The hot and cold water supplies should be flushed thoroughly before installation of this rough valve.  
Damage to the cartridges caused by debris is not covered by the warranty.

Summary of Contents for 06630XX0

Page 1: ...3 Hole Roman Tub Rough 3 Hole Roman Tub Trim Kits Installation Instructions Warranty...

Page 2: ...t should be installed by a licensed professional plumber Large differences in pressure between the hot and cold supplies should be balanced The included connecting tubes are type K copper tubing If an...

Page 3: ...rface Install the stop rings and escutcheon adapters on the valves When installed correctly the stop rings will stop the escutcheon adapters at the proper mounting height Lower the valves so that the...

Page 4: ...0 06109XX0 Scroll handle 06121XX0 06044XX0 06108XX0 Lever handle 06120XX0 06043XX0 06107XX0 These trim kits are for use with rough 06607000 The rough must be installed and the mounting sur face comple...

Page 5: ...Tango C scroll handles shown Limbo C lever handles shown Swing C cross handles shown 06630XX0 06574XX0 06651XX0...

Page 6: ...andles All models Remove the plaster shields from the hot and cold valves and spout tee Position the handle over the stem with the lever or cross in the desired off position Hold the lever or cross wi...

Page 7: ...he plug from the spout tee Swing C only Install the deco ring on the spout Make sure that the set screw hole in the deco ring lines up with the set screw hole on the spout All models Push the spout se...

Page 8: ...ator 13956XX0 9 set screw 96029000 10 Solaris handle 88569XX0 11 Stratos handle 88571XX0 12 Metro handle 88570XX0 13 cross handle 88614XX0 14 scroll handle cold 88613XX0 scroll handle hot 88643XX0 15...

Page 9: ...14 15 16 17 18 19 20 20 7 7 7 8 8 8 9 9 9 Swing C Tango C Limbo C 13...

Page 10: ...s and Showers Acids are a necessary ingredient of cleaning materials for removing lime however please pay attention to the following points when cleaning faucets and showers Only use cleaning material...

Page 11: ...0455 In requesting warranty service you will need to provide 1 The sales receipt or other evidence of the date and place of purchase 2 A description of the problem 3 Delivery of the product or the de...

Page 12: ...Hansgrohe Inc 1490 Bluegrass Lakes Parkway Alpharetta GA 30004 Tel 770 360 9880 Fax 770 360 9887 www hansgrohe usa com US Installation Instructions Part No 90964701 Revised 12 2009...

Reviews: