Assembly
STEP 13
Tank/Gas Line Connection
Leak Test
1. Make 2-3 oz of leak detection solution by mixing one part liquid dishwashing soap with three
parts water.
2. Make sure control knob is in the “OFF” position.
3. Connect LP gas tank per “Installing LP Gas Tank” section.
4. Turn LP gas tank valve to “OPEN”.
5. Spoon several drops of solution, or use a squirt bottle, at all “X” locations (figure 1 and 2).
a. If any bubbles appear, turn LP gas tank valve to “CLOSED”, reconnect and re-test.
b. If you continue to see bubbles after several attempts, turn LP gas tank valve to “CLOSED”
and disconnect LP gas tank, per “Disconnecting LP Gas Tank”. Contact 1-866-988-3300
for assistance.
c. If no bubbles appear after one minute, turn LP gas tank valve to “CLOSED”, wipe away
solution and proceed.
FHTS80073A
23
OFF
Figure 1
Figure 2