74
75
Alarm
This option allows the user to select the alarm settings:
Alarm State
and
Alarm Limits
. If the
Alarm
option
is enabled, a continuous double beep will be heard, along with the “
Alarm
” indicator blinking on the LCD,
each time the set limits in
Measure
mode are exceeded.
Note:
Alarm Beeper must be set On for audible beep to be heard. See:
System Setup
→
Beeper
→
Alarm
.
Alarm State
Three settings are available for the Alarm State option:
Disabled
- the alarm will be disabled.
Inside Limits
- the alarm state will trigger when the measured value is inside the set limits.
Outside Limits
- the alarm state will trigger when the measured value is outside the set limits.
To set the Alarm State:
• Press
while in
Conductivity
mode.
• Press
.
• Use
or
to select the
Alarm
option.
• Press
and use
or
highlight the
Alarm
State
option.
• Press
and use
or
to highlight the
desired option.
• Press
to confirm your selection or press
to
cancel operation.
Alarm Limits
This option allows the user to set the alarm limits for the measured value.
Note
: The Alarm High value can not be lower than the Alarm Low value.
• Press
while in
Conductivity
mode.
• Press
.
• Use
or
to select the
Alarm
option.
• Press
and use
or
highlight the
Alarm
Limits
option.
• Press
and then use
or
to set the
desired value, then press
to save the modified value or
press
to cancel operation.
• Press
return to the
Alarm
options.
• Press
and use
or
to highlight the desired parameter to be logged in file.
• Press
to enable the parameter or
to disable it.
• Press
to return to previous menu.
Sampling Period
This option allows the user to select the desired sampling period for automatic logs.
To set the Sampling Period:
• Press
while in
Conductivity
mode.
• Press
.
• Use
or
to highlight the
Log
option.
• Press
and use
or
to highlight the
Sampling Period
option.
• Press
and use
or
to select the desired
option.
• Press
to confirm your selection or press
to
cancel operation.
New Lot
This option is used to create a new lot when manual logging is used.
Note
: If
New Lot
option is accessed and the
Logging Type
is
Automatic
, a warning message appears on the LCD
informing the user that a new lot can be created only if the
Logging Type
is set as
Manual
.
To generate a New Lot:
• Press
while in
Conductivity
mode.
• Press
.
• Use
or
to select the
Log
option.
• Press
and use
or
to highlight the
New Lot
option.
• Press
to generate a new manual lot. A pop-up menu will be displayed asking for confirmation.
• Press
to confirm or press
to escape without saving and return to the
Log
options.