Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for a correct
operation. Please read it carefully before using the meter.
If you need additional technical information, do not hesitate
to e-mail us at [email protected].
This instrument is in compliance with the 

 directives.

Remove the instrument from the packing material and ex-
amine it carefully. If any damage has occurred during
shipment, immediately notify your Dealer or the nearest
Hanna Customer Service Center.

The meter is supplied with:

• Screwdriver
• 12 Vdc power adapter

Note: Conserve all packing material until the instrument has

been observed to function correctly. Any defective item
must be returned in its original packing.

PRELIMINARY EXAMINATION

  HI  982401 is an ORP meter specially designed to

meet the needs of monitoring ORP such as in swimming
pools. The housing has been completely sealed against
vapors and humidity with IP54 rating. Simply hang the 
above the sample to be monitored.

The HI 3214P/2 gel-filled ORP electrode (optional) is inter-
changeable and the BNC connector is protected behind a
waterproof sheath. The unique design of the electrode pro-
vides longer life even in harsh conditions.

GENERAL DESCRIPTION

1

HI 3214P/2

Double fiber junction, plastic body, Platinum
ORP electrode with 2 m (6.6’) cable and BNC
connector

HI 7020M

ORP test solution at 200/275 mV, 230 mL

HI 7020L

ORP test solution at 200/275 mV, 500 mL

HI 7091M

Reducing solution, 230 mL

HI 7091L

Reducing solution, 500 mL

HI 7092M

Oxidizing solution, 230 mL

HI 7092L

Oxidizing solution, 500 mL

HI 7061L

Electrode cleaning solution, 500 mL bottle

HI 710005

12 Vdc power adapter, US plug

HI 710006

12 Vdc power adapter, European plug

HI 710012

12 Vdc power adapter, Australian plug

HI 710013

12 Vdc power adapter, Southern Africa plug

HI 710014

12 Vdc power adapter, UK plug

ACCESSORIES

CE DECLARATION OF CONFORMITY

Recommendations for Users
Before using this product, make sure that it is
entirely suitable for the environment in which it
is used. Operation of this instrument in residen-
tial areas could cause unacceptable interferences
to radio and TV equipment.
During operation, ESD wrist straps should be
worn to avoid possible damage to the electrode
by electrostatic discharges.
Any variation introduced by the user to the
supplied equipment may degrade the instrument’s
EMC performance.
To avoid electrical shock, do not use this
instrument when voltages at the measurement
surface exceed 24 Vac or 60 Vdc.
To avoid damages or burns, do not perform any
measurement in microwave ovens.

6

Summary of Contents for Pronto HI 982401

Page 1: ... accident misuse tampering or lack of prescribed maintenance are not covered If service is required contact the dealer from whom you purchased the instrument If under warranty report the model number date of purchase serial number and the nature of the failure If the repair is not covered by the warranty you will be notified of the charges incurred If the instrument is to be returned to Hanna Inst...

Page 2: ... longer life even in harsh conditions GENERAL DESCRIPTION 1 HI 3214P 2 Double fiber junction plastic body Platinum ORP electrode with 2 m 6 6 cable and BNC connector HI 7020M ORP test solution at 200 275 mV 230 mL HI 7020L ORP test solution at 200 275 mV 500 mL HI 7091M Reducing solution 230 mL HI 7091L Reducing solution 500 mL HI 7092M Oxidizing solution 230 mL HI 7092L Oxidizing solution 500 mL ...

Page 3: ...er while mak ing sure the gasket is in place before tightening the screws Whenever the mV reading is lower than the setpoint the red alarm LED blinks to warn the user Maintenance To minimize clogging and provide longer life to the ORP electrode it si recommended to clean it monthly Immerse the tip of the electrode in HI 7061 cleaning solution for at least one hour and then rinse it with tap water ...

Page 4: ...trode optional Casing IP54 Power Supply 12 Vdc adapter included Dimensions 86 x 110 x 43 mm 3 4 x 4 3 x 1 7 Weight 150 g 5 3 oz SPECIFICATIONS 3 P R When not in use rinse the electrode with water and store it with the protective cap If the electrode has been left dry soak the tip in HI70300 storage solution for at least one hour to reactivate it Taking ORP Measurements Turn the meter on Remove the...

Reviews: