Hanna Instruments pH 209 Instruction Manual Download Page 11

21

20

ELECTRODE APPLICATION

REFERENCE GUIDE

Application

Electrodes

1. Aquarium

HI 1332B, HI 1911B

2. Bath-water

HI 1910B, HI 1130B

3. Beer

HI 1131B

4. Bread

HI 2031B, FC 200B

5. Cheese

FC 200B

6. Dairy products

FC 911B, FC 100B

7. Dirty water

HI 1910B, HI 1912B

8. Emulsions

HI 1053B

9. Environment

HI 1230B

10. Flasks

HI 1331B

11. Food industry general use

FC 911B, FC 100B

12. Fruit

FC 200B, FC 220B

13. Fruit juices, organic

FC 210B

14. Galvanizing waste solution

HI 1130B, HI 1912B

15. Heavy-duty applications

HI 1135B

16. High purity water

HI 1053B

17. Horticulture

HI 1053B, FC 200B

18. In-line applications

HI 1134B, HI 1135B, HI 2114B, HI 2910B

19. Laboratory general use

HI 1131B, HI 1230B, HI 1332B, HI 1330B

20. Leather

HI 1413B

21. Lemon juice

FC 100B

22. Meat

FC 200B, HI 2031B

23. Micro plate sampling of less than

HI1083B

100  mL

24. Milk and Yogurt

FC 210B

25. Paints

HI 1053B

26. Paper

HI 1413B

27. Photographic chemicals

HI 1230B

28. Quality control

HI 1332B

29. Sausages

FC 200B, HI 2031B

30. Semisolid products

HI 2031B

31. Skin

HI 1413B

32. Soil samples

HI 1230B

33. Solvents

HI 1043B

34. Strong acid

HI 1043B

35. Submersion application

HI 1130B

36. Surface measurements

HI 1413B

37. Swimming pool

H I1130B, HI 2114B, HI 2910B

38. Titrations with constant

HI 1131B

temperature range

39. Titrations with wide temperature

HI 1131B

range

40. Very high humidity

FC 911B, HI 1912B, HI 1911B

41. Vials and test tube

HI 1330B

42. Wine processing

FC 220B

Extension cables for screw-type electrodes (screw to BNC
adapter)
HI 7855/1

Extension cable 1m (3.3') long

HI 7855/3

Extension cable 3m (9.9') long

HI 7855/5

Extension cable 5m (16.5') long

HI 7855/10

Extension cable 10m (33') long

HI 7855/15

Extension cable 15m (49.5') long

OTHER ACCESSORIES

HI 710005

Voltage adapter from 115 Vac to 12 Vdc

HI 710006

Voltage adapter from 230 Vac to 12 Vdc

ChecktempC

Pocket-size thermometer (range -50.0 to 150.0°C)

HI 76405

Electrode holder

HI 8427

pH and ORP electrode simulator with 1 m (3.3')
coaxial cable ending in female BNC connectors

HI 931001

pH and ORP electrode simulator with LCD and 1 m
(3.3') coaxial cable ending in female BNC connectors

CONNECT TO
SCREW TYPE

ELECTRODES

CONNECT TO THE

BNC SOCKET

OF THE METER

HI 7855 SERIES CABLE CONNECTORS

CONNECTOR AND 3.0 mm (0.12") CABLE WITH BNC

Summary of Contents for pH 209

Page 1: ...Instruction Manual w w w h a n n a i n s t c o m pH 209 pH 209R Bench Top pH Meters ...

Page 2: ...2B plastic body combination double junction refillable pH electrode with BNC connector and 1m 3 3 cable 12 Vdc adapter Instruction manual Note Save all packing material until you are sure that the instru ment functions correctly All defective items must be returned in the original packing with the supplied accessories Dear Customer Thank you for choosing a Hanna Instruments Product Please read thi...

Page 3: ...09R only 0 to 14 pH 1999 to 1999 mV Temperature always 0 Input Impedance 1012 ohm Power Supply 12 Vdc adapter included Environment 0 to 50 C 32 to 122 F RH max 95 non condensing Dimensions 240 x 182 x 74 mm 9 4x7 2x2 9 Weight approx 1 0 kg 2 2 lb SPECIFICATIONS 1 Liquid Crystal Display LCD 2 pH slope adjustment knob 3 pH offset adjustment knob 4 pH range selection key 5 mV range selection key 6 C ...

Page 4: ...tch again to switch the instrument off Power connection Plug the supplied 12 Vdc adapter into the power supply socket 9 on page 4 Note Make sure the mains line is protected by a fuse Electrode connection For combination pH or ORP electrodes with internal reference connect the electrode s BNC to the socket provided 10 on page 4 For an electrode with a separate reference connect the measuring electr...

Page 5: ... 1 into the solution Note If you need to calibrate to NBS standards use pH 6 86 HI 7006 and pH 9 18 HI 7009 instead of pH 7 01 and 10 01 respectively Use a ChecktempC or a glass thermometer as reference PROCEDURE Switch the instrument on by pressing the ON OFF button Rinse and immerse the pH electrode into pH 7 01 buffer and shake briefly Wait for the reading to stabilize pH CALIBRATION Note the t...

Page 6: ... pH The calibration buffer solutions are affected by temperature changes to a lesser degree than normal solutions For manual temperature calibration please refer to the following chart For instance if the buffer temperature is 25 C the display should show pH 4 01 7 01 or 10 01 at pH 4 7 or 10 buffers respectively At 20 C the display should show pH 4 00 7 03 or 10 06 The meter reading at 50 C will ...

Page 7: ...oughly in distilled water and then follow the Cleaning Procedure above For refillable electrodes If the filling solution electrolyte is more than 2 cm 1 below the fill hole add HI 7082 3 5M KCl electrolyte solution for double junction or HI 7071 3 5M KCl AgCl electrolyte solution for single junction electrodes For a faster response unscrew the fill hole screw during measure ments For AmpHel electr...

Page 8: ...electrodes HI 8072 1M KNO3 electrolyte solution in FDA bottle 4 x 30 mL HI 8082 3 5M KCl electrolyte solution in FDA bottle 4 x 30 mL for double junction electrodes Alkaline Error 1 0 Mol L 1 Na 0 1 Mol L 1 Na Sodium Ion Correction for the Glass at 20 25 C Concentration pH Error 13 00 13 50 14 00 12 50 13 00 13 50 14 00 0 10 0 14 0 20 0 10 0 18 0 29 0 40 TEMPERATURE RESISTANCE CORRELATION FOR HANN...

Page 9: ...ed with a BNC connector and 1 m 3 3 cable HI 1043B Glass body double junction refillable combination pH electrode Use strong acid alkali HI 1053B Glass body triple ceramic conic shape refillable combination pH electrode Use emulsions HI 1083B Glass body micro Viscolene non refillable combination pH electrode Use biotechnology micro titration HI 1131B Glass body single junction refillable combinati...

Page 10: ...lectrode Use very high humidity 120 mm 4 7 12 mm 0 5 FC 100 75 mm 2 95 6 mm 0 25 FC 200 120 mm 4 7 12 mm 0 5 FC 210 120 mm 4 7 12 mm 0 5 9 5mm DIA 0 37 FC 220 HI 1413B Glass body single junction flat tip Viscolene non refillable combina tion pH electrode Use surface measurement ORP ELECTRODES HI 3131B Glass body refillable combination platinum ORP electrode Use titration HI 3230B Plastic body gel ...

Page 11: ...oilsamples HI 1230B 33 Solvents HI 1043B 34 Strongacid HI 1043B 35 Submersionapplication HI 1130B 36 Surfacemeasurements HI 1413B 37 Swimmingpool H I1130B HI 2114B HI 2910B 38 Titrationswithconstant HI 1131B temperaturerange 39 Titrationswithwidetemperature HI 1131B range 40 Veryhighhumidity FC 911B HI 1912B HI 1911B 41 Vialsandtesttube HI 1330B 42 Wineprocessing FC 220B Extension cables for screw...

Page 12: ...ave ovens WARRANTY All Hanna Instruments meters are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions The electrodes and the probes are guaranteed for a period of six months This warranty is limited to repair or replacement free of charge Damage due to accident misuse tampering or lack of prescribed m...

Page 13: ...942 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011 615 8582 Taiwan Tel 886 2 2739 3014 Fax 886 2 2739 2983 Thailand Tel 66 2619 0708 Fax 66 2619 0061 UnitedKingdom Tel 01525 850 855 Fax 01525 853 668 USA Tel 401 765 7500 Fax 401 765 7575 For e mai...

Reviews: