Please examine this product carefully. Make sure that the instrument is not damaged. If any damage 
occurred during shipment, please contact your local Hanna Instruments Office.
Each 

HI96733

 Ion Selective Meter is supplied complete with: 

 

• Sample Cuvettes and Caps (2 pcs.)

 • 

CAL Check

TM

 standard cuvettes

 

• 9V Battery

 

• Tissue for wiping cuvettes

 

• Instrument quality certificate

 

• Instruction Manual and Quick Reference Guide

 

• Rigid carrying case

Note: Save all packing material until you are sure that the instrument works correctly. Any 

defective item must be returned in its original packing.

PRELIMINARY EXAMINA

TION

Summary of Contents for HI96733C

Page 1: ...INSTRUCTION MANUAL HI96733C Ammonia High Range ISM...

Page 2: ...the instrument as well as a precise idea of its versatility If you need additional technical information do not hesitate to e mail us at tech hannainst com or view our worldwide contact list at www ha...

Page 3: ...PRINCIPLE OF OPERATION FUNCTIONAL DESCRIPTION ERRORS AND WARNINGS GENERAL TIPS FOR AN ACCURATE MEASUREMENT STARTUP MEASUREMENT PROCEDURE VALIDATION PROCEDURE CALIBRATION PROCEDURE GLP BATTERY MANAGEM...

Page 4: ...ve Meter is supplied complete with Sample Cuvettes and Caps 2 pcs CAL CheckTM standard cuvettes 9V Battery Tissue for wiping cuvettes Instrument quality certificate Instruction Manual and Quick Refere...

Page 5: ...ications Display messages aid the user in routine operation The meter has an auto shut off feature that will turn off the instrument after 10 minutes of non use in measurement mode or after 1 hour if...

Page 6: ...Environmental Technology D1426 92 Nessler Method The reaction between ammonia and the reagents causes a yellow tint in the sample Environment 0 to 50 C 32 to 122 F max 95 RH non condensing Battery Typ...

Page 7: ...ND ACCURACY Absorption of Light is a typical phenomenon of interaction between electromagnetic radiation and matter When a light beam crosses a substance some of the radiation may be absorbed by atoms...

Page 8: ...nt conditions Whenever possible use the same cuvette for both It is necessary that the surface of the cuvette is clean and not scratched This to avoid measurement interference due to unwanted reflecti...

Page 9: ...ds to start a pre programmed countdown prior to measurement In GLP mode press to view the next screen CAL CHECK this is a bi functional key Just press to perform the validation of the meter or press a...

Page 10: ...gs 3 The battery icon shows the charging level of the battery 4 The hourglass appears when an internal checking is in progress 5 Status messages 6 The chronometer appears when the reaction timer is ru...

Page 11: ...check the preparation of the zero cuvette Light Low There is not enough light to perform a measurement Please check the preparation of the zero cuvette No Light The instrument cannot adjust the light...

Page 12: ...e condition The concentration of the sample is beyond the programmed range dilute the sample and re run the test c during calibration procedure Standard Low The standard reading is less than expected...

Page 13: ...attery must be replaced soon Dead battery This indicates that the battery is dead and must be replaced Once this indication is displayed the meter will lock up Change the battery and restart the meter...

Page 14: ...n the top the bottom of this concavity must be at the same level of the 10 mL mark In order to measure exactly 0 5 mL of reagent with the 1 mL syringe a push the plunger completely into the syringe an...

Page 15: ...such bubbles by swirling or by gently tapping the cuvette Do not let the reacted sample stand too long after reagent is added or accuracy will be lost It is possible to take multiple readings in a ro...

Page 16: ...sate the meter for the sample turbidity or color the measurement takes place in two phases First the meter is zeroed using the unreacted sample After the reagents are added the reacted sample is measu...

Page 17: ...y will show 0 0 The meter is now zeroed and ready for measurement Using the plastik pipette add 9 mL of HI93733B 0 Ammonia Reagent B up to the 10 mL mark Place the cap and swirl the solution to mix Pl...

Page 18: ...sitioned securely into the groove Press and hold READ TIMER for three seconds The display will show the countdown prior to measurement The beeper is playing a beep at the end of countdown period MEASU...

Page 19: ...ive error To eliminate these interferences distillation is required Sulfide S2 may cause turbidity Hardness above 1 g L as Calcium Carbonate CaCO3 At the end of measurement the instrument directly dis...

Page 20: ...se perform test at room temperature 18 to 25 C 64 5 to 77 0 F Turn the meter on by pressing ON OFF When the beeper sounds briefly and the LCD displays dashes the meter is ready VALIDATION PROCEDURE Pr...

Page 21: ...ector icons together with CAL CHECK will appear on the display depending on the measurement phase At the end of the measurement the display will show the validation standard value The reading should b...

Page 22: ...at room temperature 18 to 25 C 64 5 to 77 0 F Turn the meter on by pressing ON OFF When the beeper sounds briefly and the LCD displays dashes the meter is ready Press and hold CAL CHECK for three sec...

Page 23: ...kTM Standard HI96733 11 Cuvette B into the cuvette holder and ensure that the notch on the cap is positioned securely into the groove Press READ TIMER and the lamp cuvette and detector icons will appe...

Page 24: ...2005 appears on the display or 01 01 2005 if the factory calibration was selected before In both cases the year number is blinking ready for date input Press GLP to edit the desired year 2000 2099 If...

Page 25: ...pressing READ TIMER Press GLP to edit the desired month 01 12 If the key is kept pressed the month number is automatically increased When the correct month has been set press ZERO CFM or READ TIMER to...

Page 26: ...on the secondary display If no calibration was performed the factory calibration message F CAL will appear on the main display and the instrument returns to measurement mode after three seconds FACTOR...

Page 27: ...instrument asks for confirmation of user calibration delete Press ZERO CFM to restore the factory calibration or press GLP again to abort factory calibration restore The instrument briefly notifies d...

Page 28: ...750 measurements depending on the light level The remaining battery capacity is evaluated at the instrument startup and after each measurement The instrument displays a battery indicator with three le...

Page 29: ...e down and remove the battery cover by turning it counterclockwise Extract the battery from its location and replace it with a fresh one Insert back the battery cover and turn it clockwise to close To...

Page 30: ...Other Accessories HI96733 11 CAL CheckTM Standard Cuvettes 1 set HI742009P 9V battery 10 pcs HI731318 Cloth for wiping cuvettes 4 pcs HI731331 Glass cuvettes 4 pcs HI731335 Caps for cuvettes 4 pcs HI...

Page 31: ...ding to the instructions This warranty is limited to repair or replacement free of charge Damages due to accident misuse tampering or lack of prescribed maintenance are not covered If service is requi...

Page 32: ...a Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com Local Office Hanna Instruments USA 270 George Washington Highway Smithfield RI 02917 Phone 800...

Reviews: