12

13

HI70605/2

Detachable interchangeable TFPC RH probe with 2 m

(6.6') cable and perforated cap (for HI 9065 only)

HI70605/5

Detachable interchangeable TFPC RH probe with 5 m

(16.5') cable and perforated cap (for HI 9065 only)

HI70607/2

Detachable interchangeable TFPC RH probe with 2 m
(6.6') cable and sintered cap (for HI 9065 only)

HI70607/5

Detachable interchangeable TFPC RH probe with 5 m

(16.5') cable and sintered cap (for HI 9065 only)

HI70608/2

Detachable interchangeable TFPC RH probe with 2 m

(6.6') cable (for HI 9064 and HI 9160 only)

HI70608/5

Detachable interchangeable TFPC RH probe with 5 m
(16.5') cable (for HI 9064 and HI 9160 only)

HI7101

Calibration chambers for probes with perforated cap,

complete with O-ring and precalibrated saturated salts

HI7111/P

Spare saturation salts 6 x 15 g bottles of LiCl for low

range humidity calibration

HI7121/P

Spare saturation salts 6 x 33 g bottles of NaCl for high
range humidity calibration

HI 710031

Hard carrying case

HI 721308

1.5V AA size alkaline battery (10 pcs)

MANRHWPR2

Instruction manual

FOR  HI9065  ONLY

Interchangeable precalibrated temperature probes:
HI765AN

Air Temperature Probe

HI765FN

Surface Temperature Probe

HI765LN

Liquid     Temperature Probe

HI765PN

Penetration Temperature Probe

HI9064

,       

HI9065  

and       

HI9160 

are supplied with the advanced

"BEPS" Battery Error Preventive System technology that detects a low

power condition in the battery and prevents erroneous measurements
being taken due to low voltage.
For       

HI 9064

 and      

HI 9065

, upon depletion of the power in the

batteries up to a prefixed threshold, the LCD automatically switches

off.
For      

HI9160

, when the batteries are low "V"

is displayed on the LCD to warn the user. This

is to inform the user that the display will be
shut-off after about 5 hours of use.
Battery replacement must only take place in a non hazardous area
using the battery types specified in this instruction manual (see page

13).

In order to replace rundown batteries, simply
remove the two screws on the rear cover of

the instrument and replace the four 1.5V AA

batteries with new ones, paying attention to
the correct polarity.

V

"BEPS"  &  BATTERY  REPLACEMENT

"BEPS"  &  BATTERY  REPLACEMENT

"BEPS"  &  BATTERY  REPLACEMENT

"BEPS"  &  BATTERY  REPLACEMENT

"BEPS"  &  BATTERY  REPLACEMENT

ACCESSORIES

ACCESSORIES

ACCESSORIES

ACCESSORIES

ACCESSORIES

Summary of Contents for HI9064

Page 1: ...HI9065 HI9160 Portable Water Resistant Hygrometers HI 9065 Thermo Hygrometer ON OFF HOLD RH C F RH C F 5 95 0 60 C 32 140 F s H h t t p w w w h a n n a i n s t c o m These Instruments are in Complian...

Page 2: ...ler Note Save all packing material until you are sure that the instrument functions correctly All defective items must be returned to us in the original packing with the supplied accessories The HI906...

Page 3: ...064 H 9064 H 9064 H 9064 H 9064 HI I I I I9065 9065 9065 9065 9065 HI 9065 Thermo Hygrometer HI 9064 Hygrometer ON OFF HOLD RH ON OFF C F HOLD RH C F RH 5 95 5 95 0 60 C 32 140 F 1 7 8 9 3 2 5 4 2 3 6...

Page 4: ...come into contact with water or other liquids If this should happen or if condensation causes drops to form on the surface of the humidity sensor turn off the instrument and wait until they have evapo...

Page 5: ...he walls of the glass container Li Cl 11 1 Na Cl 75 4 CALIBRATION KIT H 2 O 26 cc L i C l CALIBRATION CALIBRATION CALIBRATION CALIBRATION CALIBRATION C C F TEMPERATURE MEASUREMENTS FOR HI9065 ONLY Con...

Page 6: ...t in use as the LiCl solution is extremely hygroscopic and tends to capture the humidity present in the air causing the solution to expand in volume and overflow from the container Pour approximately...