Recommendations for Users

Before using these products, make sure that they are entirely suitable

for the environment in which they are used.
Operation of these instruments in residential areas could cause unac-

ceptable interferences to radio and TV equipment.
The metal band at the end of the probe is sensitive to electrostatic dis-

charges. Avoid touching this metal band at all times.
During operation, ESD wrist straps should be worn to avoid possible dam-

age to the probe by electrostatic discharges.
Any variation introduced by the user to the supplied equipment may de-

grade the instrument’s EMC performance.
To avoid electrical shock, do not use these instruments when voltages at the

measurement surface exceed 24 VAC or 60 VDC.
Use plastic beakers to minimize any EMC interferences.
To avoid damages or burns, do not perform any measurement in micro-

wave ovens.

PRINTED IN CANADA ISTRHI150R2  09/2004

h t t p : / / w w w . h a n n a c a n . c o m

Hanna Instruments reserves the right to modify the

design, construction and appearance of its products

without advance notice.

W A R R A N T Y

W A R R A N T Y

W A R R A N T Y

W A R R A N T Y

W A R R A N T Y

HI 150-00/10 thermometer is warranted for one year

against defects in workmanship and materials when

used for their intended purpose and maintained ac-

cording to instructions.

 The sensor are warranted for a

period of one year also.

 This warranty is limited to

repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed

maintenance are not covered.
If service is required, contact the dealer from whom you purchased the

instrument. If under warranty, report the model number, date of pur-

chase, serial number and the nature of the failure. If the repair is not

covered by the warranty, you will be notified of the charges incurred. If

the instrument is to be returned to Hanna Instruments, first obtain a

Returned Goods Authorization Number from the Customer Service de-

partment and then send it with shipment costs prepaid. When shipping

any instrument, make sure it is properly packaged for complete protec-

tion.
To validate your warranty, fill out and return the enclosed warranty card

within 14 days from the date of purchase.

All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna
Instruments Inc.

• Replace the rear panel and the gasket, ensuring

the unit is properly closed.

• Move the switch to the left (SET Mode).

• With a small

screwdriver adjust the setpoint trimmer to dis-
play the desired value in the  0 to 50 ºC or -20

to 20ºC  range (based on the model).

• Make sure the switch is moved back to the right

(MEASURE Mode).

• To utilize the relay function open the casing as

explained for setpoint calibration.
After wiring close the  casing properly. The relay
wires should pass through the access hole.

• Whenever the temperature reading reaches the

setpoint ( considering the hysteresis ), the  alarm
LED blinks and relay is activated.