Hanna Instruments HI 9914 Instruction Manual Download Page 17

33

32

- Air bubbles also disturb measurements and the probe should be

installed in such a way as to minimize them.

Note

It is always recommended to keep at least one spare probe

handy. When anomalies are not resolved with a simple mainte-
nance, change the electrode (and recalibrate the controller) to see
if the problem is alleviated.

Note

Ensure that the probe is installed in such a way that it perma-
nently lies in the solution whether in the tank or the circulation
pipe.

ACCESSORIES

pH electrodes
HI 1001

pH electrode for continuous flow-through monitoring

HI 1002

pH electrode for continuous flow-through monitoring

HI 1003

pH electrode with matching pin

EC probes
HI 7632/D

Conductivity probe, ATC, 1/2” thread, with DIN
connector and 2 m (6.6’) cable,  for continuous flow-
through monitoring up to 3 atm pressure

HI 3003/D

Conductivity probe, ATC, Pt-ring, Kynar

®

 body,

1/2” thread, with DIN connector and 2 m (6.6’)
cable, for continuous flow-through monitoring up to
6 atm pressure

pH calibration solutions
HI 7004L

pH 4.01 buffer solution, 500 mL bottle

HI 7007L

pH 7.01 buffer solution, 500 mL bottle

HI 7010L

pH 10.01 buffer solution, 500 mL bottle

EC calibration solutions
HI 7031L

1.41 mS/cm calibration solution, 500 mL bottle

HI 7039L

5.00 mS/cm calibration solution, 500 mL bottle

Maintenance solutions
HI 70300L

Electrode storage solution, 500 mL bottle

HI 7061L

General cleaning solution, 500 mL bottle

Other accessories
BL1.5, BL3, BL5, BL7, BL10, BL15, BL20

Dosing pumps with flow rate from 1.5 to 18.3 lph
(0.4 to 4.8 gph)

APPENDIX - A

pH VALUES AT VARIOUS TEMPERATURES.

The temperature directly affects the pH value.
For example, if the buffer’s temperature is 25°C (77°F), calibrate the
meter to read 7.01, 4.01 or 10.01; if the temperature is 20°C, calibrate
the meter to 7.03, 4.00 or 10.06; if the temperature is 50°C, calibrate
the meter to 6.98, 4.06 or 9.82; etc.
Please refer to the following chart for a more accurate pH calibration.

TEMP

pH VALUES

°C

°F

4.01

6.86

7.01

9.18

10.01

0
5

10
15
20
25
30
35
40
45
50
55
60
65
70

32
41
50
59
68
77
86
95

104
113
122
131
140
149
158

4.01
4.00
4.00
4.00
4.00
4.01
4.02
4.03
4.04
4.05
4.06
4.07
4.09
4.11
4.12

6.98
6.95
6.92
6.90
6.88
6.86
6.85
6.84
6.84
6.83
6.83
6.84
6.84
6.85
6.85

7.13
7.10
7.07
7.04
7.03
7.01
7.00
6.99
6.98
6.98
6.98
6.98
6.98
6.99
6.99

9.46
9.39
9.33
9.27
9.22
9.18
9.14
9.10
9.07
9.04
9.01
8.99
8.97
8.95
8.93

10.32
10.24
10.18
10.12
10.06
10.01

9.96
9.92
9.88
9.85
9.82
9.79
9.77
9.76
9.75

Summary of Contents for HI 9914

Page 1: ...1 Instruction Manual HI 9914 Wall mounted Fertigation Controller w w w h a n n a i n s t c o m...

Page 2: ...y on two large LCDs with backlight feature for a best easy reading TheECprobeisdesignedwithabuilt intemperaturesensorwhichallows the controller to automatically compensate for the temperature effect T...

Page 3: ...erdosing of fertilizer or acid The controller is designed with relay outputs for pH and conductivity control 2A 240V each one corresponding to a status LED for visual check Three level sensors are use...

Page 4: ...eeding pump output 20 Circulation pump output 21 Alarm output 1 LCD for Conductivity readings 2 EC SET button 3 EC slope adjustment trimmer 4 EC MEAsure button 5 Alarm LED 6 Reset button 7 LCD for pH...

Page 5: ...djustable from 0 5 to 14 0 pH Calibration Manual 2 point with offset 2 pH and slope 80 to 120 trimmers Analogoutput 0 7V 5 0 5V pH Controller Output 2A 220V relay Other Features Timer Adjustable from...

Page 6: ...erenttankvolumesandwithvariouscomplex ity of tank assembly For proper operation of the controller the tank assemblies must be set minding the following the pH electrode and EC probe should rapidly det...

Page 7: ...less of the water composition or level The controllerwillrefillthetankifthewatergoesundernormallevelforabout 15 minutes or if the fill button is pressed Note The inlet of the circulation pump must be...

Page 8: ...the NC pin when is on the COMMON pin is connected with the NO pin The NC pin is not accessible for the pH and EC pumps and the COMMON Place the low level sensor to indicate the minimum water level fo...

Page 9: ...onnect one pin of the source to the COMMON pin of the alarm output Connect the alarm device between the NO output pin and the remaining source pin Acid and fertilizer dosing pump connection The pH and...

Page 10: ...ke sure the controller is completely wired and all the connections for pumps alarm probes etc have been done Connect the mains power wires to the power supply input pins Replace the right panel lid an...

Page 11: ...e conductivity and pH values are good for at least 30 seconds the controller goes to step 5 If the normal level sensor remains open for about 15 minutes the controller goes back to step 3 Step 5 The C...

Page 12: ...is reached SETTINGTHEECCONTROL To adjust the Conductivity setpoint Push the SET button close to EC display to read the setpoint value ALARM CONDITIONS When an alarm condition is reached the ALARM LED...

Page 13: ...swillbeactivefor 3 minutes and off for 12 minutes 3 12 15 minutes Setting the timer In order to activate the timed dosing feature put the TIMED CONT switch to the TIMED position To set the duty cycle...

Page 14: ...25 C Immerse the probe in the beaker ensuring that the holes on the probe sleevearecompletelycovered CALIBRATION Disconnect the pumps the water nozzle and the alarm or assure that the start of one of...

Page 15: ...trode stem or bulb If any scratches or cracks are present replace the electrode The connector must be perfectly clean and dry Cleaning procedure Soak the electrode in HI 7061 General Cleaning Solution...

Page 16: ...perly or constantly reads zero or a value close to it Check the probe and cable for cracks and replace it if needed If the controller display shows 1 The cable may be shorted or the probe broken Repla...

Page 17: ...ottle EC calibration solutions HI7031L 1 41 mS cm calibration solution 500 mL bottle HI7039L 5 00 mS cm calibration solution 500 mL bottle Maintenancesolutions HI70300L Electrode storage solution 500...

Page 18: ...ystem utilized in nursery and cutting plants cultivation Reference Principitecnico agronomicidellafertirrigazioneedelfuorisuolo pag 115 publishedby VenetoAgricoltura CentroSperimentaleOrtofloricoloPod...

Page 19: ...37 36 APPENDIX C INSTALLATIONEXAMPLES Block diagram for a typical installation of an irrigation system with HI9914controller Block diagram for an irrigation system with recirculation circuit...

Page 20: ...ribed main tenance are not covered This warranty is limited to free of charge or replacement of the meter only if any malfunctioning is due to manufac turing defects If service is required contact the...

Page 21: ...942 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax...

Reviews: