background image

Instruction Manual

HI 991001

Extended Range Waterproof

pH / Temperature Meter

Dear Customer,

Thank you for choosing a Hanna Instruments

Product.

This instrument is in compliance with the

 directives.

All Hanna Instruments

 meters are warranted

for two years 

against defects in workmanship

and materials when used for their intended pur-

pose and maintained according to instructions.

The probes are warranted for a period of

six months.

This warranty is limited to repair or replacement

free of charge

Damage due to accidents, mis-

use, tampering or lack of prescribed maintenance

are not covered.
If service is required, contact the dealer from

whom you purchased the instrument. If under

warranty, report the model number, date of pur-

chase, serial number and the nature of the prob-

lem. If the repair is not covered by the warranty,

you will be notified of the charges incurred. If the

instrument is to be returned to Hanna Instru-

ments, first obtain a Returned Goods Authoriza-

tion Number from the Customer Service depart-

ment and then send it with shipment costs pre-

paid. When shipping any instrument, make sure it

is properly packaged for complete protection.

All rights are reserved. Reproduction in whole or

in part is prohibited without the written consent of

the copyright owner.

WARRANTY

PRELIMINARY EXAMINATION

Remove the instrument from the packing

material and examine it carefully to make

sure that no damage has occurred during

shipment. If noticeable damage is evident,

notify your dealer.

Note:

Save all packing material until you

are sure that the instrument func-

tions correctly. All defective items

must be returned in the original

packing together with the supplied

accessories.

HI 991001 

is a portable, microprocessor-

based pH and temperature meter.
Main features include: extended pH and

temperature ranges; waterproof and com-

pact casing; large dual-line display; low

battery detection; automatic pH calibration

at one or two points with two memorized

buffer sets (standard or NIST); selectable

temperature unit (°C or °F).
The pH electrode has a built-in tempera-

ture sensor for simultaneous pH and tem-

perature readings, and also contains a mini

amplifier to render measurements imper-

vious to noise and electrical interferences.
Each meter is supplied complete with

 

HI 1296D

 pH/temperature probe with DIN

connector and 1 m (3.3’) cable

 calibration & cleaning solution sachets

 3x1.5V AA alkaline batteries

• 

instruction manual

• 

rugged carrying case.

GENERAL DESCRIPTION

SPECIFICATIONS

Range (*)

-2.00 to 16.00 pH

-5.0 to 105.0°C / 23.0 to 221.0°F

Resolution

0.01 pH

0.1°C / 0.1°F

Accuracy (@20°C)

±0.02 pH

±0.5°C up to 60°C; ±1°C outside

±1°F up to 140°F; ±2°F outside

Typical EMC

±0.02 pH

Deviation

±0.2°C or ±0.4°F

Temperature

Automatic

Compensation
pH Calibration

Automatic, 1 or 2 point

with 2 sets of memorized buffers

(pH 4.01/7.01/10.01 or 4.01/6.86/9.18)

Probe

 (included)

HI 1296D

amplified pH/temperature

probe with DIN connector and 1 m (3.3’) cable

Battery Type

3 x 1.5V AA / IEC LR6

Battery Life

Approx. 2000 hours

Auto-off

After 8 minutes of non-use

Environment

0 to 50°C (32 to 122°F);

RH max 100%

Dimensions

150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)

Weight

210 g (7.4 oz.)

(*)

 

the temperature range is limited to 80°C (176°F) if

using the HI1296D probe.

To clean the meter, use water only.

HI 1296D

Combination amplified pH/

temperature probe with DIN

connector and 1 m (3.3’) cable

HI 7004L

pH 4.01 buffer solution, 500 mL

HI 7006L

pH 6.86 buffer solution, 500 mL

HI 7007L

pH 7.01 buffer solution, 500 mL

HI 7009L

pH 9.18 buffer solution, 500 mL

HI 7010L

pH 10.01 solution, 500 mL

HI 70300L

Storage solution, 500 mL

HI 7061L

Cleaning solution, 500 mL

HI 710007

Blue shockproof rubber boot

HI 710008

Orange shockproof rubber boot

HI 721312

Rugged carrying case

HI 76405

Electrode holder

ACCESSORIES

LCD DESCRIPTION

1. Automatic Temperature Compensation

    indicator

2. Stability indicator

3. Battery percentage

4. pH calibration indicator

5. Low battery indicator

6. Selectable temperature unit

7. Secondary display

8. Primary display

9. Measuring unit for primary display

    

IST991001R2        07/05

w w w . h a n n a i n s t . c o m

Hanna Instruments reserves the right to

modify the design, construction and appear-

ance of its products without advance notice.