4
HI98713
is a high accuracy ISO compliant portable turbidimeter that benefits from Hanna Instruments’
years of experience as manufacturer of analytical instruments. The
HI98713
meets and exceeds the
requirements of the
ISO 7027
for water quality.
The instrument is specially designed for water quality measurements, providing a reliable and accurate
reading on low turbidity values.
The
HI98713
instrument measures the turbidity of a sample in the 0.00 to 1000 FNU (Formazin
Nephelometric Units) range. An effective algorithm calculates and converts the detectors output in FNU.
Depending on the measured probe and needed accuracy, normal measurement, continuous measu‑
rement, or signal averaging measurement can be selected.
The instrument is based on a state‑of‑the‑art optical system, which guarantees accurate results. The
optical system, consisting in an infrared LED and two detectors (scattered and transmitted light),
assures long term stability and minimizes stray light and color interferences. It also compensates for
variations in intensity of the LED, minimizing the need of frequent calibration.
The 25 mm round cuvettes made from special optical glass guarantee the repeatability and consistency
of the measurements.
Calibration can be easily performed at any time in two, three or four points (<0.1, 15, 100 and 750
FNU‑adjustable calibration points), using the supplied or user prepared standards.
HI98713
has complete GLP (Good Laboratory Practice) functions that allows traceability of the calibra‑
tion conditions. The last calibration points, time and date can be checked at any time by a single touch.
HI98713
has a very user‑friendly interface, with an easy to read, large LCD (Liquid Crystal Display).
The displayed codes guide the user step by step with routine operation and through calibration.
Confirmation and acoustic signals help the user during instrument operation.
The
HI98713
turbidimeter is a truly splash proof portable instrument. It is supplied with a rigid
carrying case that offers protection for harsh environments.
One battery set is enough for at least 1500 measurements. The battery charging percentage and low
battery condition are displayed on the LCD to avoid unexpected battery failure. In order to save the
battery life, the instrument has an auto shut‑off feature and will turn off after 15 minutes of non‑use.
In addition, the instrument is equipped with backlight and the current time is continuously displayed
on the LCD.
The instrument also provides a logging function. Up to 200 measurements can be stored in the internal
memory and consulted at any time. Data can be downloaded to a PC for storing or further analysis
through one of the two available ports: RS232 or USB.
For advanced field applications, the
HI98713
turbidimeter is equipped with Tag Identification System
(TIS) that makes data collecting and management simpler than ever.
GENERAL DESCRIPTION