Preliminary Examination

Remove the tester and accessories from the packing material and 
examine it carefully. If you require any further information, please contact 
Hanna Instruments technical support team at [email protected].
Each 

HI98311

 is delivered in a cardboard box and is supplied with:

• 

HI70031

 1413 µS/cm conductivity standard, 20 mL sachet (3 pcs.)

• 

HI70032

 1382 ppm TDS standard, 20 mL sachet (3 pcs.)

• 

HI73311

 EC/TDS probe

• 

HI73128

 Probe removal tool

• 1.5V batteries
• Instrument quality certificate
• Instruction manual
Each 

HI98312

 is delivered in a cardboard box and is supplied with:

• 

HI70030

 12880 µS/cm conductivity standard, 20 mL sachet (3 pcs.)

• 

HI70038

 6.44 ppt TDS standard, 20 mL sachet (3 pcs.)

• 

HI73311

 EC/TDS probe

• 

HI73128

 Probe removal tool

• 1.5V batteries
• Instrument quality certificate
• Instruction manual

Note: 

Save all packing material until you are sure that the tester 

works correctly. Any damaged or defective item must be returned 

in its original packing material with the supplied accessories.

General Description & Intended Use

HI98311

 (DIST

®

5) and 

HI98312

 (DIST

®

6) are compact EC/TDS 

and temperature testers. They feature a two-buttons operation 
system and are easy to use. The compact and waterproof casing is 
designed to float if accidentally dropped in water. The testers measure 
temperature in °C and °F and all EC /TDS readings are temperature 
compensated automatically (ATC).
EC/TDS measurements have user-selectable conversion factor (CONV) 
and temperature compensation coefficient ß (beta).
The testers display a stability tag ( ) that will disappear once the 
reading has stabilized.

Battery level and low-battery indicator are clearly displayed on 
the LCD to alert the user in the event that low battery power could 
adversely affect readings.

BEPS (Battery Error Prevention System)

The testers will automatically shut off if there is not enough power to 
get an accurate measurement.

EC/TDS Probe

HI98311

 & 

HI98312

 are supplied together with 

HI73311

 EC/TDS 

graphite electrode.

Temperature Sensor

The stainless steel temperature sensor facilitates faster and more 
accurate temperature measurements.

Specifications

Range

0.0 to 60.0 °C (32.0 to 140.0 °F)
0 to 3999 µS/cm (

HI98311

)

0.00 to 20.00 mS/cm (

HI98312

)

0 to 2000 ppm (

HI98311

)

0.00 to 10.00 ppt (

HI98312

)

Resolution

0.1 °C (0.1 °F)
1 µS/cm ; 1 ppm (

HI98311

)

0.01 mS/cm ; 0.01 ppt (

HI98312

)

Accuracy 
(@25 °C / 77 °F)

±0.5 °C (±1.0 °F)
±2% f.s. (EC/TDS)

Temperature
compensation

Automatic
ß=0.0 to 2.4% / ºC

Environment

0 to 50 °C (32 to 122 °F); RH 100%

TDS Factor

0.45 to 1.00 (CONV)

Calibration

Automatic, one-point

Calibration solutions

HI98311

HI98312

HI70031

 (1413 µS/cm)

HI70032

 (1382 ppm; CONV=0.5)

HI70442

 (1500 ppm; CONV=0.7)

HI70030

 (12880 µS/cm)

HI70038

 (6.44 ppt; CONV=0.5

or 9.02 ppt; CONV=0.7)

Electrode

HI73311

 EC/TDS electrode (included)

Battery type

1.5V (4 pcs.)

Battery life

Approx. 100 hours

Auto-off

After 8 minutes of non-use

Dimensions

171 x 41 x 26 mm (6.7 x 1.6 x 1.0”)

Weight

85 g (3.1 oz.)

Functional Description

Liquid Crystal 

Display
SET/HOLD 

button

Battery 

compartment

/MODE 

button

Temperature 

sensor

HI73311 EC/TDS 

probe 

LCD Display

5

6

7

8

4

3

2

1

1.  Automatic Temperature Compensation (ATC) indicator
2.  Stability tag
3.  Battery life percentage indicator
4.  Low battery indicator
5.  Measurement units (

HI98311

)

6.  Measurement units (

HI98312

)

7.  First LCD line
8.  Second LCD line

Operational Guide

Turning the Tester ON / OFF

Press and hold  /MODE. All LCD segments will be displayed for a 
few seconds followed by battery life percentage indicator. To turn the 
tester off, from measurement mode, press  /MODE. “OFF” will be 
displayed on the second LCD line and then the tester will turn off.

HOLD Mode 

From measurement mode, press and hold 
SET/HOLD until “HOLD” is displayed. EC/TDS 
readings will be frozen on the LCD. Press either 
buttons to resume measurement mode.

Setup

Setup mode allows the selection of temperature unit. To enter the setup 
mode, press  /MODE until “TEMP” and the current temperature unit are 
displayed (e.g. “TEMP °C”). Use SET/HOLD to change the temperature 
unit. To return to measurement mode, press  /MODE twice.

EC / TDS Calibration & Measurement

It is recommended to calibrate the tester frequently, especially if high 
accuracy is required. More frequent calibrations may be required 
depending on the type of sample being tested. The tester should be 
recalibrated:
• whenever the EC/TDS electrode is replaced
• at least once a month
• after testing aggressive samples

Calibration procedure

• From measurement mode, press and hold  /MODE until “CAL” is 

displayed on the second LCD line.

• Place the probe in calibration solution: 

HI70031

 (1413 µS/cm) 

for 

HI98311

 and 

HI70030

 (12.88 mS/cm) for 

HI98312

.

• The LCD displays “OK” for 1 second and the tester returns to 

measurement mode.

• When using the calibrations solutions listed in the Specifications 

table, if the EC / TDS conversion factor is either 0.50 or 0.70, the 
tester allows a direct calibration in ppm.

Note: 

The “CAL” tag on the LCD indicates that the tester is 

calibrated.

Exiting Calibration & Resetting Default Values

• When in calibration mode, it is possible to exit calibration 

procedure by pressing  /MODE, before first-point calibration 
has been accepted. The tester displays “ESC” and returns to 
measurement mode and last calibrated data.

• When in calibration mode, it is possible  to clear a previous 

calibration and return to default values by pressing SET/HOLD, 
before the first calibration point has been accepted. The tester 
displays  “CLR” on the second LCD line, “CAL” tag dissappears and 
tester returns to default calibration.

Summary of Contents for HI 98311

Page 1: ...HI98311 HI98312 Waterproof EC TDS Temperature Testers INSTRUCTION MANUAL ...

Page 2: ...n manual Each HI98312 is delivered in a cardboard box and is supplied with HI7003012880µS cmconductivitystandard 20mLsachet 3pcs HI70038 6 44 ppt TDS standard 20 mL sachet 3 pcs HI73311 EC TDS probe HI73128 Probe removal tool 1 5V batteries Instrument quality certificate Instruction manual Note Save all packing material until you are sure that the tester works correctly Any damaged or defective it...

Page 3: ...140 0 F 0 to 3999 μS cm HI98311 0 00 to 20 00 mS cm HI98312 0 to 2000 ppm HI98311 0 00 to 10 00 ppt HI98312 Resolution 0 1 C 0 1 F 1 μS cm 1 ppm HI98311 0 01 mS cm 0 01 ppt HI98312 Accuracy 25 C 77 F 0 5 C 1 0 F 2 f s EC TDS Temperature compensation Automatic ß 0 0 to 2 4 ºC Environment 0 to 50 C 32 to 122 F RH 100 TDS Factor 0 45 to 1 00 CONV Calibration Automatic one point Calibration solutions ...

Page 4: ...tton Temperature sensor HI73311 EC TDS probe LCD Display 5 6 7 8 4 3 2 1 1 Automatic Temperature Compensation ATC indicator 2 Stability tag 3 Battery life percentage indicator 4 Low battery indicator 5 Measurement units HI98311 6 Measurement units HI98312 7 First LCD line 8 Second LCD line ...

Page 5: ...r the EC TDS electrode is replaced at least once a month after testing aggressive samples Calibration procedure From measurement mode press and hold MODE until CAL is displayed on the second LCD line Place the probe in calibration solution HI70031 1413 μS cm for HI98311 and HI70030 12 88 mS cm for HI98312 The LCD displays OK for 1 second and the tester returns to measurement mode When using the ca...

Page 6: ...50 CONV and SET HOLD to change the conversion factor Press MODE to show the current temperature compensation coefficient ß e g 2 1 BETA and SET HOLD to change the temperature compensation coefficient ß Press MODE to return to measurement mode Maintenance Please read the information below to ensure the highest possible accuracy If measurements are taken successively rinse the probe thoroughly in di...

Page 7: ...t four new 1 5V AA batteries in the battery compartment while paying attention to the correct polarity figure 2 5 Close the battery compartment using the four screws fig 2 Note Only use the battery type specified in the manual Old batteries should be disposed in accordance with local regulations Accessories Electrodes HI73311 Replaceable EC TDS probe HI73128 Electrode removal tool Solutions HI7003...

Page 8: ...ore the tester in hazardous environments Warranty HI98311 and HI98312 are warranted for a period of one year against defects in workmanship and materials when used for their intended purpose and maintained according to instructions The electrode is warranted for a period of six months This warranty is limited to repair or replacement free of charge Damage due to accidents misuse tampering or lack ...

Reviews: