Hanna Instruments HI 98140 Manual Download Page 4

P/L HI98150_INC   1.0   PRINTED IN US

A

SPECIFICATIONS

HI 98140

HI 98150

HI 98160

Range

pH

-4.0 to 20.0 pH; -4.00 to 19.99 pH

mV

±699.9; ±2000 mV

Temperature

20.0 to 120.0°C / -4.0°F to 248.0°F

Resolution

pH

0.1 pH; 0.01 pH

mV

0.1 mV; 1 mV

Temperature

0.1°C / 0.1°F

Accuracy
(@20°C)

pH

±0.1 pH; ±0.01 pH

mV

±0.2 mV (±699.9 mV); ±1 mV (±2000)

Temperature

±0.2°C (±0.4°F) excluding probe error

SMART Electrode Compatible

Yes

Auto-endpoint Feature

Yes

pH Calibration

up to 3 point (HI 98140) or up to 5 point (HI 98150)

calibration with 7 standard buffers (1.68, 4.01, 6.86, 7.01,

9.18, 10.01, 12.45), and 2 custom buffers

up to 5 points with 8 standard buffers

(1.68, 3.00, 4.01, 6.86, 7.01, 9.18,

10.01, 12.45) and 2 custom buffers

Offset Calibration

±1 pH

Slope Calibration

From 80 to 108%

Rel mV Offset Range

±2000 mV

Temperature Compensation

automatic or manual, -20 to 120°C (-4 to 248°F)

automatic or manual, -20 to 120°C (-

4 to 248°F) without temperature

probe

pH Electrode

HI 1618D amplified pH electrode with built-in temperature

sensor, plastic body and DIN connector (included)

HI 1230B, double junction, PEI body,

gel filled, BNC connector and 1 m

(3.3’) cable (included)

Temperature Probe

HI 7662 with 1 m (3.3’) cable

(included)

Logging

on-demand, 500 samples

PC Connection

opto-isolated USB

Input Impedance

10

12

Ohm

Battery Type / Life

(4) 1.2V AAA / approx. 200 hours of continuous use (with backlight off); 

auto-off after 20 minutes of non-use (can be disabled) (HI 98140 and HI 98150); 

user-selectable auto shut-off (5, 10, 20, 60 min or disabled) (HI 98160)

Environment

0 to 50°C (32 to 122°F); RH max 100%

Dimensions / Weight

192 x 71.6 x 36 mm (7.5 x 2.8 x 1.4’’) / 425 g (15 oz.)

ORDERING INFORMATION

HI 98140 

and  

HI 98150

are supplied with HI 1618D Amplified

pH electrode with built-in temperature sensor, EEPROM and DIN
connector, starter set of calibration solution sachets, (4) 1.2 AAA
batteries, instructions and carrying case.

HI 98160

is supplied with HI 1230B combination double-

junction, gel-filled pH electrode, HI 7662 stainless steel
temperature probe with 1 m (3.3’’) cable, starter set of
calibration solution sachets, (4) 1.2 AAA batteries,  instructions
and carrying case.

ELECTRODES

HI 1230B

pH electrode, double junction, PEI body, BNC 
connector, 1 m (3.3’) cable

HI 1618D

“SMART” pre-amplified pH electrode 
with PEI body and DIN connector

HI 3620D

Pre-amplified ORP electrode with PEI body 
and DIN connector

HI 3620D

“SMART” Pre-amplified ORP electrode with glass 
body and DIN connector

HI 7662

Temperature probe

SOLUTIONS

HI 5004L

pH 4.01 buffer solution, 500 mL

HI 5007L

pH 7.01 buffer solution, 500 mL

HI 5010L

pH 10.01 buffer solution, 500 mL 

HI 70300L

Electrode storage solution, 500 mL

HI 7061L

Electrode cleaning solution, 500 mL

ACCESSORIES

HI 92000

Windows® compatible software

HI 920013

USB connection cable

w w w . H A N N A N O R D E N . c o m