Instruction Manual
HI 93746
Iron Low Range ISM
HI 93746 is warranted for two years
against defects in
workmanship and materials when used for its intended purpose and
maintained according to instructions.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of purchase,
serial number and the nature of the failure. If the repair is not covered
by the warranty, you will be notified of the charges incurred. If the
instrument is to be returned to Hanna Instruments, first obtain a Returned
Goods Authorization Number from the Customer Service department
and then send it with shipment costs prepaid. When shipping any
instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty card
within 14 days from the date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments
Inc., Woonsocket, Rhode Island, 02895 , USA.
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for the correct
operation of the meter. Please read it carefully before using
the meter. If you need additional technical information, do
not hesitate to e-mail us at [email protected].
This instrument is in compliance with directives.
Remove the instrument from the packing material and
examine it carefully to make sure that no damage has
occurred during shipment. If there is any damage, notify
your Dealer.
Each Ion Specific Meter is supplied complete with
• 9V Battery
• Two Sample Cuvets and Caps
• One Transport Cap
Note:
Conserve all packing material until the instrument
has been observed to function correctly. Any defective
item must be returned in its original packing.
The
HI 93746
meter measures the iron content in water,
wastewater and seawater in the 0 to 400 µg/L (ppb)
range.
The meter uses an exclusive positive-locking system to ensure
that the cuvet is in the same place every time it is placed
into the measurement cell.
The reagent is in powder form and is supplied in packets.
The amount of reagent is precisely dosed to ensure maximum
repeatability.
Display codes aid the user in routine operations.
The meters have an auto-shut off feature that will turn the
instrument off after 10 minutes of non-use.
SPECIFICATIONS
Range
0 to 400 µg/L
Resolution
1 µg/L
Accuracy
±10 µg/L ±8% of reading
Typical EMC
±1 µg/L
Deviation
Light Source
Light Emitting Diode @ 555 nm
Method
Adaptation of the TPTZ Method. The reaction
between iron and the reagent causes a
violet tint in the sample
Light Detector
Silicon Photocell
Environment
0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Battery
Type/Life
1 x 9 volt/40 hours
Auto-Shut off
After 10' of non-use
Dimensions
180 x 83 x 46 mm (7.1 x 3.3 x 1.8")
Weight
290 g (10 oz.)
REQUIRED REAGENTS
Code
Description
Quantity/test
HI 93746-0
Iron LR Reagent
2 packets
(1 packet for blank)
(1 packet for sample)
REAGENT SETS
HI 93746-01
Reagents for Iron LR (100 packets)
HI 93746-03
Reagents for Iron LR (300 packets)
w w w . h a n n a i n s t . c o m
This Instrument is in
Compliance with the CE Directives
HANNA instruments®
reserves the right to modify the design,
construction and appearance of its products without advance notice.
General Description
Preliminary Examination
Warranty
Specifications
IST93746R3 11/06
This indicates that the meter is in a ready
state and zeroing can be performed.
Sampling in Progress. This prompt appears
each time the meter is performing a
measurement.
This indicates that the meter is in a zeroed
state and measurement can be performed.
A zero reading was not taken. Insert a
sample before adding reagent and press
ZERO.
Under range. A blinking "0" indicates
that the sample absorbs less light than the
zero reference. Check the procedure and
make sure you use the same cuvet for
reference (zero) and measurement.
Over range. A flashing value higher than
the maximum concentration readable (see
specifications) indicates that the sample
absorbs too much light, meaning that the
concentration is too high. Dilute the sample.
Light over range. The cuvet is not inserted
correctly and an excess ambient light is
reaching the detector. If the cover is
properly installed, then contact your dealer
or the nearest Hanna Customer Service
Center.
Light under range. The zero sample is too
dark for proper zeroing. If this is not the
case, contact your dealer or the nearest
Hanna Customer Service Center.
The "V" indicates that the battery voltage
is getting low and the battery needs to be
replaced.
This indicates that the battery is dead and
must be replaced.
Note:
once this indication is displayed,
the meter will lockup. Change the battery
to restart.
Display Code Guide