Hanna Instruments HI 93510 Instruction Manual Download Page 2

3

2

PRELIMINARY EXAMINATION

Remove the instrument from the packing material and examine it to
make sure that no damage has occurred during shipping. If there is
any damage, notify your dealer or the nearest Hanna Customer
Service Center.

Each meter is supplied complete with:
• Temperature probe
• 3 x 1.5V AA alkaline batteries
• Instruction manual.

Note:

 Save all packing material until you are sure that the

instrument functions correctly. All defective items must be
returned in the original packing with the supplied accessories.

Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the instru-
ment.
This manual will provide you with the necessary information for correct
use of the instrument, as well as a more precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at 

[email protected]

.

These instruments are in compliance with the 

 directives.

GENERAL DESCRIPTION

HI 93510

HI 93510N

HI 93512

 and 

HI 93522

 are powerful and

flexible thermistor thermometers, which have been designed using the
latest microprocessor technology to provide reliable and accurate
measurements.
Standard features include waterproof casing, dual-level LCD, low
battery detection, long battery life and two-year warranty.

HI 93510

 has been designed for laboratory and field use, while 

HI

93510N

 is suitable for high accuracy (meter and probe can be

calibrated in an ice bath at 0°C) or dimly lit areas (the backlight
feature can be easily activated through the keyboard).

HI 93512

 is a two-channel thermometer, ideal for monitoring two

samples at once, while 

HI 93522

 offers all the features of 

HI 93512

and more: calibration of meter and probe at 0°C, backlight, user-
selectable auto-off time period, and capability to store and recall a
reading.

WARRANTY

All Hanna Instruments 

meters are warranted for two years

 against defects in

workmanship and materials when used for their intended purpose and maintained
according to instructions. 

The

 

probes are warranted for a period of six months

.

This warranty is limited to repair or replacement free of charge.
Damages due to accidents, misuse, tampering or lack of prescribed maintenance are
not covered.
If service is required, contact the dealer from whom you purchased the instrument. If
under warranty, report the model number, date of purchase, serial number and the
nature of the failure.
First obtain a Returned Goods Authorization number from the Customer Service depart-
ment, then return the instrument with the Authorization number included along with
shipment costs prepaid.
If the repair is not covered by the warranty, you will be notified of the charges.
When shipping any instrument, make sure it is properly packaged for complete
protection.

TABLE OF CONTENTS

PRELIMINARY EXAMINATION ........................................................ 3
GENERAL DESCRIPTION ................................................................ 3
SPECIFICATIONS OF HI 93510 AND HI 93510N ........................... 4
SPECIFICATIONS OF HI 93512 AND HI 93522 ............................. 6
OPERATIONAL GUIDE ................................................................... 8
USER CALIBRATION .................................................................... 12
FACTORY RECALIBRATION ........................................................... 12
BATTERY REPLACEMENT .............................................................. 13
CE DECLARATION OF CONFORMITY .............................................. 14
TEMPERATURE PROBES .............................................................. 15

Summary of Contents for HI 93510

Page 1: ...Instruction Manual HI 93510 HI 93510N HI 93512 HI 93522 PortableMicroprocessor ThermistorThermometers w w w h a n n a i n s t c o m...

Page 2: ...and probe can be calibrated in an ice bath at 0 C or dimly lit areas the backlight feature can be easily activated through the keyboard HI 93512 is a two channel thermometer ideal for monitoring two...

Page 3: ...obes series Available HI 762 accuracy test plugs Display of temperature in degrees Celsius or Fahrenheit Range 50 to 150 C or 58 to 302 F HOLD function HI and LO Max and Min temperature values always...

Page 4: ...with HI 762BL probe Battery 3x1 5V AA IEC LR6 batteries approx 2000 hours of continuous use BL off Auto off user selectable 8 min 60 min disabled HI 93522 only Environment 10 to 50 C 14 to 122 F RH 1...

Page 5: ...mpartment see figure on page 10 Unscrew the 4 screws on the back of the meter and select the desired auto off time period by pressing the button and viewing the value on the LCD Reattach the back maki...

Page 6: ...light up to inform the user To select the desired channel use the T1 T2 key The 2 channel models are also provided with the DISP function which allows the user to select the information to be displaye...

Page 7: ...then automatically returns to normal mode Note To exit the Calibration mode at any time press the CAL key Note User calibration cannot be entered in relative or in T1 T2 mode Note User calibration is...

Page 8: ...obe w 10 m 33 cable white handle HI 762PBL General purpose penetration probe w 1 m 3 3 cable blue handle HI 762PBL 10 General purpose penetration probe w 10 m 33 cable blue handle HI 762PG General pur...

Page 9: ...42 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 0...

Reviews: