background image

10

2.2.7 Agitator

2.2.7 Agitator

2.2.7 Agitator

2.2.7 Agitator

2.2.7 Agitator’s connections

’s connections

’s connections

’s connections

’s connections

The same situation is true for the agitators. They can be supplied with three-phase power.
The relays that connect the power to the agitators are controlled simultaneous by the AGITATOR’S
signal.

2.2.8 Alarm device connections

2.2.8 Alarm device connections

2.2.8 Alarm device connections

2.2.8 Alarm device connections

2.2.8 Alarm device connections

A special connector is used for the alarm device command. The alarm device connections depend on
the device type. Outside the controller all contacts (NO, NC, COM OUT AL) are accessible.

2.3 CONTROLLER ST

2.3 CONTROLLER ST

2.3 CONTROLLER ST

2.3 CONTROLLER ST

2.3 CONTROLLER START

ART

ART

ART

ART-UP

-UP

-UP

-UP

-UP

After all the connections have been made according to the controller type and specifications, you
should follow the next steps:

- Disconnect the main supply from the controller (J1 connector)
- Close the K1 switch; verify if there are short-circuits (the fuse F1 blow up)
- verify the analog inputs (sensors, connections, transmitters)
- Turns OFF the Stop switch and supply the controller (connect J1)
-  After initialization the Controller State should be in the STOP state
- Go in the S50 (OUTLETS MANUAL CTRL) panel
- For each  output device connected to the controller you can verify the correct functioning step by

step. Set and clear the desired output according to the table from APPENDIX 2 (Instruction

Instruction

Instruction

Instruction

Instruction

Manual

Manual

Manual

Manual

Manual).

-  Calibrate the controller. See section  6.1 Sensor Calibration Procedure (Instruction Manual

Instruction Manual

Instruction Manual

Instruction Manual

Instruction Manual),

panel S54. This procedure should be done for each analog input that is used in installation.

- Make the program settings
- Connect the 24Vac supply (Close the K1 switch)
- Check if the installation works
- When it works, you can set the PID control. See section 6.2 PID Calibration Procedure

(Instruction Manual

Instruction Manual

Instruction Manual

Instruction Manual

Instruction Manual).

2.4 TESTING FOLLOWING INST

2.4 TESTING FOLLOWING INST

2.4 TESTING FOLLOWING INST

2.4 TESTING FOLLOWING INST

2.4 TESTING FOLLOWING INSTALLA

ALLA

ALLA

ALLA

ALLATION

TION

TION

TION

TION

The HI 8001 (2) controller has many facilities that allow the user to configure it according to his/here
purposes. To demonstrate the controller functionality you can run a lot of program setting types,
depending on the imagination. In this section we present below a controller programming sample
that try to highlight the main features.

Summary of Contents for HI 8001

Page 1: ...1 Installation Manual for technical personnel only HI 8001 and HI 8002 Agricare Fertigation Controller www hannainst com ...

Page 2: ...de contact list at www hannainst com TABLE OF CONTENTS 1 CONTROLLER HARDWARE PRESENTATION 3 1 1 Electrical specifications 3 1 2 Inputs Outputs Description 4 2 CONTROLLER INSTALLATION 6 2 1 Installation types 6 2 2 Connections Wiring 7 2 3 Controller start up 10 2 4 Testing for the customer 10 3 APPENDIX 1 ELECTRICAL DIAGRAMS 14 All rights are reserved Reproduction in whole or in part is prohibited...

Page 3: ...i D s t u p n i l a t i g i d 6 1 D N G o t t c a t n o C n i p k a e r B P M E T p o t s d n o c t n u o c g i r r i 2 1 s e r p f i d 4 3 2 1 l e v e l t r e f l e v e l d i c a l e v e l g n i x i m 5 4 3 2 1 k n a t t x e t u p n I l a i r e S e l a m 9 B D 2 3 2 S R 0 0 8 4 0 0 4 2 0 0 2 1 s p b 0 0 6 9 2 3 2 S R s t u p t u O l a t i g i D y a l e R s t u p t u o 4 3 A 0 1 p m u p n i a m s ...

Page 4: ...tal Inputs 1 2 2 Digital Inputs 1 2 2 Digital Inputs 1 2 2 Digital Inputs On the main board near the analog inputs the controller has 16 digital inputs with optical separa tion They are available only when the IN24Vac input is supplied with 24Vdc min 150mA The sensors have to be of switch type and connected to the COM IN pins near the last digital input When between a digital input and the COM IN ...

Page 5: ...ted to the COM IN pin 1 2 5 P 1 2 5 P 1 2 5 P 1 2 5 P 1 2 5 Power inputs ower inputs ower inputs ower inputs ower inputs The controller works when the 220V 110V dc power supply is connected to the 220Vac input and an auxiliary 24Vdc min 150mA voltage is connected to the IN24Vac input This source doesn t supply internally the digital outputs and should be separated from the external 24Vac power sup...

Page 6: ...architecture can be simplified pH and EC sensor number external tank number and fertilizer tank number The controller is produced in four versions 8 16 24 and 32 sectors The architecture should be clarified before starting the installation It depends on pH sensor number EC sensor number fertilizer tank number filter number external tank number differential presostate number sectors number agitator...

Page 7: ... 24Vdc 150mA source should be used for this supply It supplies the digital inputs The transformer that is used for the valves could provide the voltage for these inputs but it needs a separate winding The IN 24Vac input can be connected to the same transformer but in this case here connections with COM IN pins have to be avoided 2 2 3 Digital input connections 2 2 3 Digital input connections 2 2 3...

Page 8: ... EC in inputwill stayunconnected The transmitters will be supplied from the Vs outputs The maximum consumption supported by the controller is around 250mA 12V This means that two Hanna transmitters can be supplied from the same output 2 pH channels and 2 EC channels and one transmitter for the EC in sensor The following type of sensors can be connected to the transmitters HI 1001 HI 1001 HI 1001 H...

Page 9: ...the filters This operation is done by the four valves that are commanded alternatively two by two like in the schematic The controller provides a mechanical contact that is switched ON OFF periodically and it can be used in the installation to control the external relay see in the appendix 2 2 6 Main pump connections 2 2 6 Main pump connections 2 2 6 Main pump connections 2 2 6 Main pump connectio...

Page 10: ...Controller State should be in the STOP state Go in the S50 OUTLETS MANUAL CTRL panel For each output device connected to the controller you can verify the correct functioning step by step Set and clear the desired output according to the table from APPENDIX 2 Instruction Instruction Instruction Instruction Instruction Manual Manual Manual Manual Manual Calibrate the controller See section 6 1 Sens...

Page 11: ... conditions S34 sets External tank 02 Set program repeats S36 sets 0 Pre post Irrig S37 sets 1s Set sectors S38 sets 10s for valves 1 2 9 10 16 17 24 25 Set fertilizers S39 20 40 60 and 80 PH control S40 sets Ref 7 0 0 6 0 6 threshold 2 Cond control S41 sets Ref 7 0 0 6 0 6 Program 3 Program 3 Program 3 Program 3 Program 3 Irrig ctrl mode S53 Sets time mode Active Timetable S31 sets a valid range ...

Page 12: ...time Program 3 with repetitions Allows verifying the start condition ext tank 03 set valves irrigation time and repetitions Program 4 liked by another program Allows verifying the start condition ext tank 04 set valves and the irrigation time Sets the Start conditions S34 link 2 Starts the program 2 ext tank 02 Allows verifying the link with program 2 Manual started Goes in S47 and starts manually...

Page 13: ...Service department and then send it with shipping costs prepaid When shipping any instrument make sure it is properly packed for complete protection RECOMMENDA RECOMMENDA RECOMMENDA RECOMMENDA RECOMMENDATIONS FOR USERS TIONS FOR USERS TIONS FOR USERS TIONS FOR USERS TIONS FOR USERS Before using this product make sure it is entirely suitable for your specific application and for the environment in ...

Page 14: ...E 4 VALVE 5 VALVE 6 VALVE 7 VALVE 8 PUMP AGITATORS COM OUT 1 220 Vac 220 Vac 200 mA FILTER 1 FILTER 2 pH FERT 1 FERT 2 FERT 3 FERT 4 COM OUT 2 4 A 4 A IN 24 Vac IN 24 Vac NC ALARM NO ALARM COM OUT AL EC 1 EC 2 EC IN UNUSED UNUSED SOLAR RAD Vs 12V Vs 12V Vs 12V Vs 12V COM IN COM IN RS 232 TEMP BREAK COND STOP IRIG COUNT DIF PRES 1 DIF PRES 2 FERT LEVEL 1 FERT LEVEL 2 FERT LEVEL 3 FERT LEVEL 4 ACID ...

Page 15: ...15 DIGITAL OUTPUT ...

Page 16: ...16 ISTL8001 06 19 ...

Reviews: