Dear Customer, 

Thank you for choosing a Hanna Instruments product. Please read this 
instruction manual carefully before using the tester. 
For more information about Hanna Instruments and our products, visit  
www.hannainst.com or e-mail us at [email protected].
For technical support, contact your local Hanna Instruments Office or 
e-mail us at [email protected].

Preliminary Examination

Remove the tester and accessories from the packing material and examine 

it carefully. If you require any further information, please contact Hanna 

Instruments technical support team at [email protected].
Each 

HI981035

 is delivered in a cardboard box and is supplied with:

• 

HI70004

 pH 4.01 buffer solution, 20 mL sachet (2 pcs.)

• 

HI70007

 pH 7.01 buffer solution, 20 mL sachet (2 pcs.)

• 

HI700683 

Cleaning solution for sushi, 20 mL sachet (2 pcs.)

• 

HI9072

 Electrode storage solution, 13 mL dropper

• CR2032 3V Lithium-ion battery

• Instrument quality certificate

• Instruction manual

Note: 

Save all packing material until you are sure that the tester works 

correctly. Any damaged or defective item must be returned in its original 

packing material with the supplied accessories.

General Description & Intended Use

The 

HI981035

 Sushi pH Tester is designed to measure the pH of sushi rice 

and ensure it meets the food-hygiene and Hazard Analysis Critical Control Point 

(HACCP) regulations. It features a single button operation system and is easy to 

use. It has a compact and waterproof casing and automatic pH calibration at 

one or two points. All readings are automatically compensated for temperature 

variations with a built-in temperature sensor. The flat tip of the pH electrode 

provides optimal contact between the rice and the sensor. The pH electrode has an 

open junction design and utilizes a non-flowing gelled reference electrolyte. The 

flat tip allows the pH electrode to equilibrate quickly and reproducibly. 

Probe Features

Flat Glass Tip

The flat tip provides optimal 

surface contact for sushi rice pH 

measurements and for surfaces that 

cannot be penetrated.

pH sensitive 

glass

Open junction

Open Junction Reference

The open junction design uses a solid gel interface between the sushi rice 

sample and internal Ag/AgCl reference. This interface prevents silver from 

exiting the junction and makes it impermeable to clogging, resulting in a fast 

response and stable reading. This design allows for smaller sample sizes as 

there is no junction to submerge.

Titanium Body

Rugged and resilient, the titanium body of the probe works as an electronic shield 

protecting against interferences from electrical noise or humidity. The titanium 

body is virtually unbreakable, offering protection from accidental breakage.

Specifications

Range

0.00 to 12.00 pH

Resolution

0.01 pH

Accuracy 

±0.05 pH

Calibration

Automatic, one or two-point

Temperature compensation

Automatic, 0 to 50 °C

Electrode

Built-in probe for specific application

Battery type

CR2032 Lithium ion (included)

Battery life

Approximately 800 hours of continuous use

Auto-off

8 minutes, 60 minutes or disabled

Environment

0 to 50 °C (32 to 122 °F); RH 95% max

Dimensions

51 x 160 x 21 mm (2.0 x 6.3 x 0.9“) 

Weight

57 g (2.0 oz.)

Functional Description & LCD Display

Calibration tags

Liquid Crystal Display (LCD)

ON/OFF button

Maximum immersion level

pH sensitive glass

pH probe

Preparation

• Remove the protective cap. Do not be alarmed if salt deposits are present. 

Rinse the probe with water and blot dry.

• If the glass and / or junction are dry, soak the electrode in storage solution for 

a minimum of 30 minutes. Rinse with water and blot dry.

• Calibrate the electrode before using. For best results it is recommended to 

recalibrate periodically.

Storage

• To ensure a quick response, the glass tip and the junction should be kept moist.

• Replace protective cap with a few drops of storage solution when not in use. 

Do not store the electrode in distilled or deionized water.

Operation

Press the ON/OFF button to turn the 

tester on. The tester displays all LCD 

segments for a few seconds.

The tester will enter measurement 

mode, the current reading and 
calibrated buffers will be shown.

Calibration 

tags

Low battery 

indicator

Stability 

indicator

Measurement unit

A

One or Two-Point Calibration with pH 7.01

When "7.01" is displayed, 

place the tip of the electrode 

in pH 7.01 buffer.

When the reading is stable, the 

stability icon will disappear.

When "4.01" is displayed, follow 

the procedure to the right for a 

one or two-point calibration.

One

-P

oint

Press the ON/OFF 

button to save 

the one-point 

calibration.

"Sto" will be 

displayed when 

the calibration is 

saved.

The tester 

will return to 

measurement 

mode and the 

calibration 

tag will be 

displayed.

Two

-P

oint

Place the tip of the 

electrode in

pH 4.01 buffer. 

The buffer is 

automatically 

recognized, the 

stability indicator 

will blink.

Wait until the 

measurement is 

stable and the 

stability indicator 

dissapears. “Sto” 

will be displayed 

when the calibration 

is saved.

The tester 

will return to 

measurement 

mode and the 

calibration 

tags will be 

displayed.

One-Point Calibration with pH 4.01

B

When "7.01" is 

displayed, place the 

tip of the electrode 

in pH 4.01 buffer. 

The buffer value 

will be recognized 

automatically and 

"4.01" will be 

displayed.

When the reading 

is stable, the 

stability indicator 

will disappear. 

“Sto” will be 

displayed when 

the calibration is 

saved.

Tester will 

return to 

measurement 

mode and the 

calibration 

tag will be 

displayed.

Calibration

From measurement mode, press and hold the ON/OFF button until “CAL” is 
displayed.

  

  

For one or two-point calibration using pH 7.01 buffer solution, follow 
procedure A.

For one-point calibration using pH 4.01 buffer solution, follow 
procedure B.

Note: 

It is recommended to calibrate the electrode with buffers at the 

temperature it will be used at.

A

B

Summary of Contents for Foodcare HI981035

Page 1: ...HI981035 Sushi pH Tester INSTRUCTION MANUAL ...

Page 2: ...struction manual Note Save all packing material until you are sure that the tester works correctly Any damaged or defective item must be returned in its original packing material with the supplied accessories General Description Intended Use The HI981035 Sushi pH Tester is designed to measure the pH of sushi rice and ensure it meets the food hygiene and Hazard Analysis Critical Control Point HACCP...

Page 3: ... noise or humidity The titanium body is virtually unbreakable offering protection from accidental breakage Specifications Range 0 00 to 12 00 pH Resolution 0 01 pH Accuracy 0 05 pH Calibration Automatic one or two point Temperature compensation Automatic 0 to 50 C Electrode Built in probe for specific application Battery type CR2032 Lithium ion included Battery life Approximately 800 hours of cont...

Page 4: ... two point calibration One Point Press the ON OFF button to save the one point calibration Sto will be displayed when the calibration is saved The tester will return to measurement mode and the calibration tag will be displayed Two Point Place the tip of the electrode in pH 4 01 buffer The buffer is automatically recognized the stability indicator will blink Wait until the measurement is stable an...

Page 5: ...ation and restore the tester to factory default From calibration mode press and hold the ON OFF button the LCD will show CLr Err Message In calibration mode if the probe is in the correct buffer solution and the Err message is displayed the probe should be cleaned Soak the probe in cleaning solution for 20 minutes Rinse with water and hydrate electrode in storage solution for a minimum of 30 minut...

Page 6: ... 01 or pH 7 01 buffer can be used Never store the probe in distilled or deionized water Note Never immerse the tester over the maximum immersion level Battery Replacement To change the CR2032 lithium ion battery turn the battery cover located on the back of the tester counterclockwise to unlock Remove cover and replacethebatterywithpositive sidefacingout Note Only use the battery type specified in...

Page 7: ...on introduced by the user to the supplied equipment may degrade the tester s performance For yours and the tester s safety do not use or store the tester in hazardous environments Certification All Hanna Instruments conform to the CE European Directives Disposal of Electrical Electronic Equipment The product should not be treated as household waste Instead hand it over to the appropriate collectio...

Reviews: