Instruction Manual

HI 9241
HI 93501
HI 93501S
HI 93503
HI 935007

Portable Microprocessor

Thermometers

w w w . h a n n a i n s t . c o m

Summary of Contents for Foodcare HI 9241

Page 1: ...1 Instruction Manual HI 9241 HI 93501 HI 93501S HI 93503 HI 935007 Portable Microprocessor Thermometers w w w h a n n a i n s t c o m...

Page 2: ...nst defects in workmanship and materi als when used for their intended purpose and maintained according to instructions Electrodes and probes are guaranteed for six months This warranty is limited to...

Page 3: ...93501 HI 93501S HI 93503 and HI 935007 are professional rugged and waterproof thermometers designed to be used on a daily basis in industrial kitchens and catering They provide excellent accuracy and...

Page 4: ...50 0 to 150 0 C Resolution 0 1 C Accuracy 0 4 C excluding probe error Typical EMC Deviation 0 5 C with HI 765BL probe Battery 3 x 1 5V AAA approx 2000 hours of continuous use Auto off after 8 minutes...

Page 5: ...ff capability Waterproof casing Range 50 0 to 150 0 C Resolution 0 1 C Accuracy 0 4 C excluding probe error Typical EMC Deviation 0 4 C with HI 762PWL probe Battery 3 x 1 5V AAA approx 2000 hours of c...

Page 6: ...capability Waterproof casing Range 50 0 to 150 0 C Resolution 0 1 C Accuracy 0 4 C excluding probe error Typical EMC Deviation 0 4 C with HI 765PWL probe Battery 3 x 1 5V AAA approx 2000 hours of cont...

Page 7: ...asing SPECIFICATIONS OF HI 935007 Range 50 0 to 199 9 C 200 to 1350 C Resolution 0 1 C up to 199 9 C 1 C outside Accuracy 0 2 F S excluding probe error Typical EMC Deviation 3 C Battery 3 x 1 5V AAA a...

Page 8: ...CD segments for a few seconds followed by the percentage indication of the remaining battery life then it enters Cal Check mode and then enters measurement mode Note The full display can be frozen by...

Page 9: ...n if necessary HOLD FEATURE HI 93501S HI 93503 The hold function is activated by pressing the HOLD key The measured temperature and the stabil ity bargraph is held on the display until HOLD is pressed...

Page 10: ...ES NO PROBE message If the probe is not connected NO PROBE message is displayed DAMAGED PROBE message When the readings are very far from the reading range the probe can be dam aged DAMAGED PROBE mess...

Page 11: ...iately replace the batteries with new ones Battery replacement must only take place in a non hazardous area The batteries are accessed by opening the battery compartment cap on the bottom of the instr...

Page 12: ...id probe w 1 m 3 3 cable black handle HI 762L General purpose liquid probe w 1 m 3 3 cable white handle HI 762L 2 General purpose liquid probe w 2 m 6 6 cable white handle HI 762L 10 General purpose l...

Page 13: ...purpose penetration probe w 1 m 3 3 cable blue handle HI 765PBL 10 General purpose penetration probe w 10 m 33 cable blue handle HI 765PG General purpose penetration probe w 1 m 3 3 cable green handl...

Page 14: ...14 places w 10 m 33 cable FOR HI 935007 HI 766C Penetration K type thermocouple probe w 1 m 3 3 cable To be replaced only by authorized service technicians...

Page 15: ...e instruments in residential areas could cause unacceptable interferences to radio and TV equipment requiring the operator to follow all necessary steps to correct interferences Any variation introduc...

Page 16: ...0 Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA Technical Support for Customers Tel 800 426 6287 Fax 401 765 7575 E mail tech hannainst com www hannainst c...