background image

                                                              

 

User Manual of Fiber Laser Chiller

-25- 

 

 

S

tor

ag

e

 

en

v

iron

m

ent

 c

on

d

ition

s, 

te

m

per

a

ture:

 0~60℃, 

rel

a

ti

v

e

 h

u

m

i

d

ity:

 ≤90%. 

 

12 

Other instructions

 

12.1

S

e r v i c e   s u p p o r t

 

12.1.1

  

 

Wa

rr

a

nty

 

 

 

W

it

h

in

 24 m

ont

hs 

fro

t

h

e

 da

te

 

of

 

pur

chas

e

 

of

 

t

h

e

 

pro

d

u

c

t

 b

y

 

t

h

e

 c

o

m

p

a

ny

if

 

it

 

i

o

bv

iou

s

ly

 a 

f

a

ilure

 ca

u

s

e

d b

y

 a d

e

s

i

g

n

 d

efe

c

t

 

or

 a 

qu

a

lity

 

pro

b

le

m ca

u

s

e

d b

y

 

t

h

e

 ma

nuf

ac

turin

g, 

t

h

e

 c

o

m

p

a

ny

 

pro

v

i

d

e

free

 

rep

a

ir

s a

n

repl

ac

e

m

ent

 

p

a

rt

s. A

fter

 

t

h

e

 

w

a

rr

a

nty

 

perio

e

x

pire

s, 

p

a

i

ma

inten

a

n

c

e

 

for

 

life

 

 

12.1.2

  

 

Cas

e

not

 

wit

h

in

 

t

h

e

 sc

ope

 

of

 

t

h

e

 

w

a

rr

a

nty

 

 

 

Fa

ilure

 

to

 

in

s

t

a

ll

 

in

 acc

or

da

n

c

e

 

wit

t

h

e

 

in

s

tru

c

tion

s, 

u

s

e

 a

n

d ma

inten

a

n

c

e

or

 damag

e

 ca

u

s

e

b

y

 

e

x

tern

a

l

 c

on

d

ition

s s

u

ch as 

power

 s

upply

 

t

ha

t

 d

o

 

not

 m

eet

 

t

h

e

 

require

m

ent

s d

urin

u

s

e

D

amag

e

 ca

u

s

e

d b

y

 

i

m

proper

 

tr

a

n

s

port

a

tion

 a

n

d s

tor

ag

e

 b

y

 

our

 c

o

m

p

a

ny

.

 

M

o

d

ifi

ca

tion

to

 

our

 c

o

m

p

a

ny’

pro

d

u

c

t

or

 damag

e

 ca

u

s

e

d b

y

 

ot

h

er

 h

u

ma

n

 

f

ac

tor

s.

D

amag

e

 ca

u

s

e

d b

y

 

for

c

e

 ma

jeure

. S

u

ch as

:

 

n

a

tur

a

l

 d

i

sas

ter

s, 

w

a

r

s, 

et

c. 

D

amag

e

 ca

u

s

e

d b

y

 

in

s

t

a

ll

a

tion

 

on

 v

e

h

i

c

le

or

 sh

ip

or

 

u

s

e

d ab

ro

ad.

 

D

amag

e

 d

ue

 

to

 

equip

m

ent

 

f

a

ilure

 

 

 

 

 

 

 

 

 

 

 

12.2

O

t h e r   m a t t e r s

 

 

 

 

 

T

h

e

 

power

 s

upply

 m

u

s

t

 b

e

 

in

s

t

a

lle

in

 acc

or

da

n

c

e

 

wit

t

h

e

 

n

a

tion

a

l

 

wirin

g s

t

a

n

da

r

ds 

(

v

olt

ag

e

frequen

c

y

, a

n

pre

ss

ure

 d

ifferen

c

e

 m

u

s

t

 

m

eet

 

t

h

e

 

require

m

ent

s). I

f

 

t

h

e

 

power

 c

or

i

s damag

e

d, 

in

 

or

d

er

 

to

 

av

oi

d da

n

g

er

it

 m

u

s

t

 b

e

 

repl

ac

e

d b

y

 

profe

ss

ion

a

l

fro

t

h

e

 

ma

nuf

ac

turer'

s ma

inten

a

n

c

e

 d

ep

a

rt

m

ent

 

or

 s

i

m

il

a

r

 d

ep

a

rt

m

ent

s. 

Durin

ma

inten

a

n

c

e

t

h

e

 

power

 m

u

s

t

 b

e

 

turne

off

 

for

 3 m

inute

s b

efore

 

t

h

e

 

ma

inten

a

n

c

e

 ca

n

 b

e

 ca

rrie

out

 

 

Summary of Contents for HL--4000 Series

Page 1: ...ngjiang 1st Road Hannan District Wuhan China Post Code 430090 Email hanli laserchiller hanlizl com Tel 86 13628622086 website www hanlizl com HL 1000 1500 2000 3000 4000 6000 8000 12000 15000 20000 30...

Page 2: ...6 4 1 a d d w a t e r 14 6 4 2 Exhaust and drain 14 6 5 warm prompt 15 7 Product usage 15 7 1Check before commissioning 15 7 2 I n t r o d u c t i o n o f c o n t r o l l e r p a n e l 15 7 2 1 Introd...

Page 3: ...i s a n d e l i m i n a t i o n 21 10 circuit diagram 22 11 T r a n s p o r t a t i o n a n d s t o r a g e 24 11 1 transportation requirement 24 11 2 Storage requirements 24 12 other description 25 1...

Page 4: ...his manual is prepared for the owners and users of the chiller It includes product performance parameters appearance and component names working principles daily maintenance fault descriptions and tro...

Page 5: ...rious personal injury or death scald burn risk electrical connection a The power supply system must be selected in accordance with the relevant content of the nameplate or manual b The cable must use...

Page 6: ...e damage electric shock fire injury risk Fingers and foreign bodies should not be inserted into the equipment gaps Refrigerant leakage a When the refrigerant leaks be sure to ventilate and ventilate o...

Page 7: ...use injury and damage No trampling on the equipment Please do not board the device or sit on it otherwise it may cause injury accidents such as falling or overturning Clean the air filter regularly Cl...

Page 8: ...compresses the superheated vapor sucked from the evaporator into high temperature and high pressure gas and discharges it to the condensation The condenser releases heat into a high pressure liquid wh...

Page 9: ...r for details 2 2 M e d i u m r e q u i r e m e n t s The cooling medium must be softened water such as purified water distilled water high purity water etc ethylene glycol with volume ratio of less t...

Page 10: ...t and dual temperature two way water supply For example SCH 1500 means a handheld welding chiller with a matching laser power of 1500W a water filter is installed by default and two channel water supp...

Page 11: ...performance parameters for reference only if there is change without notice 5 Shape and component name Note The above appearance and component names are only one of the models and the appearance and c...

Page 12: ...the air inlet and 2 0m of the exhaust so as not to affect the heat dissipation of the equipment as shown in Figure 4 The product must not be installed in harsh environments such as corrosive flammable...

Page 13: ...the laser as shown in Figure 6 the inner diameter of the pipe should not be smaller than the diameter of the water inlet and outlet of the chiller If the inner diameter of the pipe is smaller than the...

Page 14: ...node signal of flow alarm and over temperature alarm 6 4 a d d w a t e r a n d a i r o u t 6 4 1 add water Add softened water to the liquid level standard area green area through the water inlet of t...

Page 15: ...ater tank is in the standard area Check whether the power source conforms to the product nameplate the 380V power cord is a three phase five wire system and the 220V power cord is a single phase three...

Page 16: ...i t c o n t r o l l e r p a n e l User Manual of Fiber Laser Chiller 7 2 2 Introduction of the integrated controller panel real time temperature setting temperature F i g 1 0 i n t e g r a t e d c o n...

Page 17: ...n t e g r a t e d c o n t r o l l e r t e m p e r a t u r e d i s p l a y PV area shows actual temperature SV area shows set temperature Low temperature water interface PV area and SV area digital tub...

Page 18: ...mperature water set temperature you need to modify F01 normal temperature water temperature difference Press the Up Down key for 5 seconds to enter the factory parameter setting state The factory sett...

Page 19: ...for a long time the water in the water tank should be drained through the drain valve and the drain screw under the water pump should be loosened to drain the remaining water in the water pump as show...

Page 20: ...ncy of maintenance is once a week The maintenance work includes but is not limited to the following aspects of work Check the condenser check whether the air duct is blocked by foreign matter and whet...

Page 21: ...robe E02 low temperature water High temperature alarm A Insufficient water flow B Poor ventilation C Too much dust Only stop low temperature hydroelectric heating A Detect B Clean up the surrounding d...

Page 22: ...cked B Clean up the surrounding debris E11 normal temperature water low temperature alarm A The temperature of the water outlet of the equipment is too low E12 normal temperature water flow alarm Stop...

Page 23: ...U W N QF PE U V W 1 2 3 Phase sequence protector M N KM3 KM4 Low temperatur e heating tube normal temperature heating tube compr essor fan K M 2 M Low temperat ure heating tube K M 3 M normal tempera...

Page 24: ...using a forklift to move the equipment make sure that the equipment is in a stable state and the height is less than 200mm from the ground and make sure to avoid the equipment casters 5 When using a c...

Page 25: ...tions such as power supply that do not meet the requirements during use Damage caused by improper transportation and storage by our company Modifications to our company s products or damage caused by...

Reviews: