Contents

MODEL NUMBER CONFIGURATION ..........................

2

1.0  INSTALLATION ...................................................

3

2.0  OPERATION .......................................................

4

3.0  MAINTENANCE .................................................

5

DIMENSIONS AND WEIGHTS .....................................

6

REPLACEMENT ELEMENTS .......................................

7

WARRANTY ..............................................................

8

General Safety Information

1. Pressurized devices

WARNING

• Do not exceed maximum operating pressure

indicated on serial number tag.

• Make certain filter is fully depressurized before

servicing.

2. Breathing Air

• Air treated by this equipment may not be suitable

for breathing without further purification.  Refer
to OSHA standard 1910.134 for breathing air
requirements.

3. Flammable gases

WARNING

While the materials of construction are compatible
with many flammable gases, the following application
limitations must be considered:

• Housing materials are slightly porous. The product

must be used in a well ventilated area in the
absence of sparks or ignition sources.  Do not use
in Class 1, Division 1, Group D environments.

• The type of area - forced exhaust system used (i.e.,

high or low level) would be dependent on the gas
involved.

• Each application (other than for air or inert gas)

must be reviewed to minimize fire or explosion
hazard.

®

Summary of Contents for HF-12

Page 1: ...icing 2 Breathing Air Air treated by this equipment may not be suitable for breathing without further purification Refer to OSHA standard 1910 134 for breathing air requirements 3 Flammable gases WARN...

Page 2: ...r none 7 General purpose air line filter 1 micron coalescer none 5 High efficiency oil removal filter High efficiency 99 99 coalescer Red 3 Ultra high efficiency oil removal filter Ultra high efficien...

Page 3: ...100 0 001 aerosols 0 01 Removes vapors only No liquid should 0 003 be present vapor B Piping 1 Before installing blow out pipe line to remove scale and other foreign matter 2 This unit has DRYSEAL pi...

Page 4: ...the various filters is indicated in Table 1a for Corrosion Resistant Models and Table 1b for High Pressure Models To determine maximum air flows at other inlet pressures multiply flow from Table 1a or...

Page 5: ...losing inlet and outlet valves 2 Depressurize filter by slowly opening manual drain valve 3 Disassemble filter housing a For High Pressure Model 24 unscrew the collar holding the filter bowl to the he...

Page 6: ...8 or 1 2 16 oz Metal 81 254 238 102 1 24 24 08 48 4 16 12 3 4 6 6 1 48 oz Metal 102 406 324 152 2 7 28 32 1 12 100 5 1 8 25 5 8 22 1 8 14 19 1 1 2 100 oz Metal 130 651 562 365 18 9 32 1 36 12 205 5 1...

Page 7: ...ment HF5 12 3 16CRS E5 16S 03 HF5 12 4 16CRS E5 16S 03 HF5 16 3 16CRS E5 20S 05 HF5 16 4 16CRS E5 20S 05 HF5 24 8 48CRS E5 24S 08 HF5 32 12 100CRS E5 32S 10 HF5 36 12 205CRS E5 36S 13 Model Element HF...

Page 8: ...ce voids the warranty and any resulting charge or subsequent claim will not be paid Products repaired or replaced under warranty shall be warranted for the unexpired portion of the warranty applying t...