Connect the device to voltage
sources, which correspond to the
electrical requirements on the label
attached to the device.
Check the wall outlet is earth-
grounded, surge-protected and
can supply enough power.
Connect the power cable to the
distribution box, or install the plug
and socket that are packed with
the device.
Switch off the device after use.
Unplug the power plug before
cleaning or unused for a long
period of time.
Check the Line Voltage
Grounded Outlet
Power Connection
Switch Off the Device
Quick Guide
Ultra 5.0
Cat. No. : UL-5.0
Cautions For Use
After centrifugation, wait until the vacuum is
released and then open the lid. (Approx. 3min)
Wipe up the moisture in the chamber with a
dry cloth after use.
Clean the chamber by wiping with a cloth
soaked in mild detergent and dry completely.
Lid Open
Keep the Chamber Dry
Cleaning
Maintenance
Electrical Safety
After using the rotor, remove the lid
and keep it upside down.
At this time, be careful not to damage
the rotor ID disc.
Rotor Stoarage
A2.0U-24
A10U-12
A13.5U-8
A13.5U-12
A38.5U-6
A38.5U-8
A50U-8
A94U-6
A250U-6
24 x 1.5/2.0 mL / Max. 40k
12 x 10 mL / Max. 45k
8 x 13.5 mL / Max. 50k
12 x 13.5 mL / Max. 50k
6 x 38.5 mL / Max. 50k
8 x 38.5 mL / Max. 45k
8 x 50 mL / Max. 40k
6 x 94 mL / Max. 40k
6 x 250 mL / Max. 25k
Rotors
After loading the rotor, press the
Rotor ID. button to identify the
rotor. (If identification fails, enter
the rotor Id. manually.
Setting Rotor ID
Bef
or
e Oper
ation
After Oper
ation
Check the rotor,buckets and
tubes are free of scratch and
crack before operation.
Check the Accessories for
Abnormalities
After relocating the device or loading the
rotor, balance them by using a leveler. If
necessary, level the device by adjusting the
‘Leveling foot’ on the bottom of the device.
Balancing the Centrifuge and Rotor
Load tubes symmetrically into the
rotor with identical amount.
Load Tubes Symmetrically
Do not press the Reset button during
cetrifugation. Pressing this button
during centrifugation, may cause the
device failure.
Do Not Press the Reset Button
Remove any dust from the ventilation
slits on the left side of the device.
Remove Dust
Allow a safety clearance of 30 cm
around the centrifuge during
operation.
Allow a Safety Clearance of 30 cm
ULTRA
30 cm
30 cm
30 cm
ULTRA, 30K콘덴서위치
3
min
ULTRA, 30K콘덴서위치
5.0KVA
220~240V 50/60Hz
Rev.01
Proudly made by Jiyoung Shim, Hyewon Jeong
Order & Inquiry l +82-2-3472-0727 l [email protected] l www.ihanil.com
Service l +82-2-3452-8966 l [email protected]