IPTV Transcoder Caster-T328
10
protective earth lead of the building installation needs to be verified.
Warning: Any interruption of the protective conductor inside or outside the
instrument, or disconnection of the protective earth terminal, is likely to make the
instrument dangerous. Intentional interruption is prohibited.
4.3
Mains Voltage Cord and Fuses
Different power cords are available for the various voltage outlets.
Note: If the mains plug has to be adapted for local use, only a qualified person should carry out this task.
This instrument is equipped with a tap-less switch mode power supply that covers most nominal voltage
ranges in use: 90-250V AC RMS. This obviates the need to adapt to the local mains voltage.
The mains frequency is 48-63 Hz.
Warning: This instrument shall be disconnected from all voltage sources when
replacing a fuse.
Mains fuse rating: 2 pcs. 1.25A slow blow, 250 V.
The mains fuse-holder is located on the rear panel of the instrument.
If the mains fuse has to be replaced please proceed as follows:
1. Remove the power cable.
2. Lift the plastic cover (fuse-holder) by means of a small screwdriver.
3. Insert the new fuse into the top of the fuse-holder.
4. Re-insert the cover (fuse-holder).
Warning: Make sure that only fuses of the required rating, voltage, and of the
specified type are used for replacement.
The use of repaired (jumpered) fuses and/or the short-circuiting of the fuse holder
are prohibited
Fuses must only be replaced by a qualified person who is aware of the hazards
involved.